Siemens 5SM3346-6KK12 — Residual Current Breakers (RCCB/RCBO)

Siemens SENTRON 5SM3346-6KK12 RCCB, 4P, 63 A, 400 V, Type A

MPN5SM3346-6KK12

Siemens SENTRON 5SM3 series RCCB, 4-pole, 63 A rated at 400 V AC, Type A fault current detection, instantaneous trip, 10 kA short-circuit current rating, DIN rail mount, IP20.

Sourced new & surplus through independent channelsAuthenticity-screened · ESD-safe packingListing updated Jul 2026

Specifications

5SM3346-6KK12 — Electrical Ratings
ParameterValue
Number of poles4
Overvoltage categoryIII
5SM3346-6KK12 — Identification
ParameterValue
Product designationRCCB
Product design / constructionInstantaneous
5SM3346-6KK12 — Mechanical
ParameterValue
Mounting positionany
Maximum45 °C
Minimum-25 °C
Width72 mm
Height90 mm
Depth77 mm
Installation depth70 mm
5SM3346-6KK12 — Environmental
ParameterValue
IP degree of protectionIP20, if the distribution board is installed, with connected conductors

Product details

The Siemens SENTRON 5SM3346-6KK12 is a 4-pole residual current circuit breaker (RCCB) rated 63 A at 400 V AC — the current-carrying capacity for a 4-wire (3L+N) supply in a standard 50 Hz distribution board. The instantaneous design (no intentional delay) trips within milliseconds of a fault, so it protects personnel but requires selectivity coordination with downstream MCBs to avoid nuisance tripping on branch faults.

Temperature derating — the real-world current limit

Above that, the continuous current must be reduced: 60.48 A at 50 °C, 57.96 A at 55 °C, 55.44 A at 60 °C, 52.92 A at 65 °C, and 50.4 A at 70 °C. If the panel internal temperature runs hot — common in sealed enclosures or near transformers — the effective capacity drops by roughly 20 % at the top end. The I²t value of 70 000 A²·s gives the energy let-through for coordination studies with upstream breakers.

Snap-on DIN rail (REG) mounting, 4 width units (72 mm wide), 77 mm depth, 90 mm height. Installation depth is 70 mm. The bottom-entry power supply cord is standard for RCCBs in this form factor. IP20 with the distribution board installed and conductors connected; finger and back-of-hand safe protection against electrical shock. Silicon-free construction suits applications where outgassing must be avoided, such as in clean rooms or sealed electronics enclosures.

Frequently asked questions

What is the difference between 5SM3346-6KK12 and 5SY4310-7CV?

The 5SY4310-7CV is a miniature circuit breaker (MCB), not an RCCB — it provides overcurrent and short-circuit protection only, without residual current detection. The 5SM3346-6KK12 detects earth leakage currents (Type A) and trips on ground faults. They serve complementary roles in a distribution board: the MCB protects the branch circuit, the RCCB protects personnel against earth faults. They are not drop-in substitutes.