Skip to main content
Siemens 5SM3346-6KL — Residual Current Breakers (RCCB/RCBO)

Siemens 5SM3346-6KL SENTRON RCCB, 63A 30mA 4P Type A

MPN5SM3346-6KL

Siemens SENTRON 5SM3 series RCCB, 4-pole Type A, 63 A rated current, 30 mA residual trip, 400 V AC, 10 kA short-circuit withstand, DIN rail mount.

Sourced new & surplus through independent channelsAuthenticity-screened · ESD-safe packingListing updated Jul 2026

Specifications

5SM3346-6KL — Electrical Ratings
ParameterValue
Number of poles4
Overvoltage categoryIII
5SM3346-6KL — Identification
ParameterValue
Product designationRCCB
Product design / constructionInstantaneous
5SM3346-6KL — Mechanical
ParameterValue
Mounting positionany
Width72 mm
Height90 mm
Depth77 mm
Installation depth70 mm
5SM3346-6KL — Environmental
ParameterValue
IP degree of protectionIP20, if the distribution board is installed, with connected conductors

Product details

The 5SM3346-6KL: Snap-on DIN rail (REG) mount, 4 width units (72 mm wide). Depth is 77 mm, installation depth 70 mm — fits standard 8-module enclosures with room for gland plates. Terminal accepts solid or stranded copper from 1.5 to 25 mm²; torque to 2.5–3 N·m. IP20 with connected conductors in an installed distribution board — not for wet or outdoor locations without an enclosure.

Ambient temperature range -25 to +45 °C operating, -40 to +75 °C storage. Mechanical service life 10,000 switching cycles typical. The part is silicon-free, which matters for potting or conformal-coating compatibility in sealed enclosures. Compliance documentation (RoHS, REACH, IEC/EN 61008) is standard with the SENTRON series; the manufacturer provides declarations on request.

Frequently asked questions

How do I get current pricing and availability for 5SM3346-6KL?

Submit an RFQ — the part is sourced through independent distribution and quoted to order, with availability and current pricing confirmed at quote time.

What is 5SM3346-6KL's listed depth?

Depth is 77 mm, with an installation depth of 70 mm.

What conductor sizes does 5SM3346-6KL accept?

Terminals accept solid or stranded copper from 1.5 to 25 mm².

Will 5SM3346-6KL drop into a panel specified around 5SY4310-7CV without rewiring?

No — the 5SY4310-7CV is a different series (MCB/RCCB hybrid) and does not drop in without verifying terminal arrangement, width, and function. The 5SM3346-6KL is a dedicated 4-pole RCCB with N left, while the 5SY series combines overcurrent and residual protection in a different footprint.

MPN
5SM3346-6KL