Siemens 5SM3412-6 — Residual Current Breakers (RCCB/RCBO)

Siemens 5SM3412-6 SENTRON RCCB, Type A, 25 A, 100 mA, 2-pole

MPN5SM3412-6

Siemens SENTRON 5SM3 RCCB, 5SM3412-6, Type A, 25 A rated, 100 mA trip, 2-pole, 230 V AC, 50 Hz, DIN rail.

Sourced new & surplus through independent channelsAuthenticity-screened · ESD-safe packingListing updated Jul 2026

Specifications

5SM3412-6 — Electrical Ratings
ParameterValue
Number of poles2
Overvoltage categoryIII
5SM3412-6 — Identification
ParameterValue
Product designationRCCB
Product design / constructionInstantaneous
5SM3412-6 — Mechanical
ParameterValue
Mounting positionany
Width36 mm
Height90 mm
Depth70 mm
Installation depth70 mm
5SM3412-6 — Environmental
ParameterValue
IP degree of protectionIP20, if the distribution board is installed, with connected conductors

Product details

The Siemens 5SM3412-6 is a 2-pole residual current circuit breaker (RCCB) from the SENTRON 5SM3 series, rated for 25 A at 230 V AC, 50 Hz, with a 100 mA trip threshold. That 100 mA sensitivity is a step above the standard 30 mA personal-protection level; it's sized for equipment protection or for circuits where nuisance tripping from leakage on long cable runs or filter caps would be a problem. The 2-pole form factor (switching both line and neutral) and the 36 mm width (2 width units on DIN rail) mean it drops into a standard distribution board without crowding adjacent breakers.

Mounting and environment — no special treatment needed

Mounts on DIN rail (REG) in any position — top or bottom feed, horizontal or vertical panel orientation — which gives the panel builder flexibility when laying out a crowded enclosure. The IP20 rating (finger-safe, with conductors connected) is standard for enclosed distribution boards; no washdown or outdoor pretensions here. The current derating curve is published: full 25 A up to 45 °C, then linearly down to 17.5 A at 70 °C. If the RCCB sits next to high-draw breakers in a sealed enclosure, that derating matters — account for the internal temperature rise.

Wire termination and panel integration

Terminals accept 1 to 16 mm² solid or stranded copper — covers everything from a 1.5 mm² lighting circuit up to a 16 mm² feeder. Installation depth is 70 mm, height 90 mm, width 36 mm.

Frequently asked questions

What is the difference between Type A and Type AC RCCBs, and why does this one use Type A?

Type A detects both sinusoidal AC fault currents and pulsating DC fault currents, which Type AC does not. This matters for circuits with electronic loads like VFDs, switch-mode power supplies, or single-phase rectifiers that can produce pulsating DC leakage. The 5SM3412-6 is Type A, so it's the correct choice for modern mixed-load panels.

What wire sizes does 5SM3412-6 accept?

Terminals accept 1 to 16 mm² solid or stranded copper conductors.

Where can I buy 5SM3412-6 and how is it quoted?

This part is sourced through independent distribution channels and quoted to order against an RFQ. Availability and current pricing are confirmed at quote time — no blanket stock or lead-time figure applies across all supply points.

MPN
5SM3412-6