Skip to main content
Siemens 5SM3417-0 — Residual Current Breakers (RCCB/RCBO)

Siemens 5SM3417-0 SENTRON RCCB, 80 A, 100 mA, 2-pole, 230 V

MPN5SM3417-0

Siemens SENTRON 5SM3417-0, RCCB, 2-pole, 80 A at 40 °C, 100 mA trip, 230 V AC, instantaneous, IP20, DIN rail mount.

StockContact for availability
MOQ1 pcs
Sourced new & surplus through independent channelsListing updated Jul 2026

Specifications

Electrical Ratings

5SM3417-0 — Electrical Ratings
ParameterValue
Number of poles2
Overvoltage categoryIII

Identification

5SM3417-0 — Identification
ParameterValue
Product designationRCCB
Product design / constructionInstantaneous

Mechanical

5SM3417-0 — Mechanical
ParameterValue
Mounting positionany
Width36 mm
Height90 mm
Depth70 mm
Installation depth70 mm

Environmental

5SM3417-0 — Environmental
ParameterValue
IP degree of protectionIP20, if the distribution board is installed, with connected conductors

Product details

The Siemens 5SM3417-0 is a SENTRON residual current circuit breaker (RCCB) rated 80 A at 40 °C, 100 mA trip sensitivity, 2-pole, 230 V AC, instantaneous type (no short-time delay). The 10 kA short-circuit current rating means it safely clears faults up to that level without upstream damage in the panel. The 100 mA trip is sized for equipment protection or circuits where a higher leakage threshold is acceptable — not the 30 mA required for personal shock protection in standard socket-outlet circuits. Mounts on DIN rail (2.5 width units, 36 mm wide, 70 mm deep), IP20 with conductors connected.

Mounting & integration

Snaps onto DIN rail (REG). Any mounting position works, but the IP20 rating assumes the distribution board is installed with conductors connected. Terminal accepts solid or stranded from 1.5 to 25 mm². Supply can enter from top or bottom. The 70 mm depth fits standard shallow enclosures — check gland plate clearance if back-panel depth is tight.

Thermal derating

Full 80 A rating holds at 40 °C and 45 °C. Above that, derate linearly: 75.2 A at 50 °C, 70.4 A at 55 °C, 65.6 A at 60 °C, 60.8 A at 65 °C, 56 A at 70 °C. Ambient range is -40 to +75 °C, but the derating curve governs continuous load above 45 °C.

Compliance & approvals

Overvoltage category III. Finger- and back-of-hand safe per protection against electrical shock. Silicon-free construction. I²t value 70 000 A²·s. Designed per DIN EN 61346-2 and DIN EN 81346-2 (function letter F). Operates at 50 Hz only.

Frequently asked questions

Where can I buy the 5SM3417-0?

Sourced and quoted to order against an RFQ through independent distribution. Availability and current pricing confirmed at quote time.

What is the 5SM3417-0 used for?

It is a residual current circuit breaker (RCCB) for equipment protection or circuits where 100 mA trip sensitivity is acceptable — typically industrial panels, not personal shock protection.

What are the key ratings of the 5SM3417-0?

80 A at 40 °C, 100 mA trip, 2-pole, 230 V AC, instantaneous, 10 kA SCCR, DIN rail mount, IP20.

MPN
5SM3417-0