Siemens 5SM3444-8LA — Residual Current Breakers (RCCB/RCBO)

Siemens SENTRON 5SM3444-8LA RCCB, 40A 100mA 4P Type A Select

MPN5SM3444-8LA

Siemens SENTRON 5SM3 series RCCB, 4-pole, Type A, selective, In: 40 A, IΔn: 100 mA, Un AC: 400 V, with thermal overload protection.

Sourced new & surplus through independent channelsAuthenticity-screened · ESD-safe packingListing updated Jul 2026

Specifications

5SM3444-8LA — Electrical Ratings
ParameterValue
Number of poles4
Overvoltage categoryIII
5SM3444-8LA — Identification
ParameterValue
Product designationRCCB
Product design / constructionSelective
5SM3444-8LA — Mechanical
ParameterValue
Mounting positionany
Maximum45 °C
Minimum-25 °C
Installation depth70 mm
5SM3444-8LA — Environmental
ParameterValue
IP degree of protectionIP20, if the distribution board is installed, with connected conductors

Product details

The Siemens SENTRON 5SM3444-8LA is a 4-pole residual current circuit breaker (RCCB) in the selective (time-delayed) design, Type A, rated 40 A at 400 V AC with a 100 mA trip threshold. The selective characteristic means it holds through short-duration earth faults and transient surges up to 5 kA surge current resistance, letting a downstream RCCB trip first — so only the faulted branch drops out, not the whole submain. That coordination matters in a distribution board feeding multiple circuits where you want the closest device to the fault to open, not the upstream main. Rated for 10 kA short-circuit current rating (SCCR) at 400 V AC, overvoltage category III, so it sits comfortably in a commercial or industrial sub-distribution board where fault levels are moderate. The 4-pole construction switches all lines including neutral, and the built-in thermal overload protection adds a second layer — it's not just a plain RCCB, it also protects against sustained overcurrent on the phase conductors.

Ambient limits and panel fit

The 45 °C ceiling is the running limit — if the panel ambient pushes above that, you need to derate or ventilate. Mounts on DIN rail (REG), any orientation, 4 width units (72 mm at 18 mm per unit), 70 mm installation depth. IP20 with connected conductors in an installed distribution board — standard for enclosed panels, not for wet locations. Finger and back-of-hand safe per the shock protection class, so live terminals are shielded when the front cover is on.

Frequently asked questions

What does the selective (time-delayed) design mean on this RCCB?

Selective means the 5SM3444-8LA is intentionally delayed to allow a downstream RCCB to trip first on a fault. This prevents a nuisance trip on the upstream main when a branch circuit has a temporary earth leakage. The surge current resistance is rated at 5 kA, so it won't false-trip on lightning or switching transients.

What is the 5SM3444-8LA's rated residual current and current rating?

Rated residual tripping current is 100 mA, rated continuous current is 40 A at 400 V AC, 50 Hz. The Type A designation means it detects AC sinusoidal fault currents plus pulsed DC fault currents up to 6 mA — covers most modern electronic loads like VFDs, switching power supplies, and LED drivers.

MPN
5SM3444-8LA