Siemens 5SM3446-8 — Residual Current Breakers (RCCB/RCBO)

Siemens 5SM3446-8 SENTRON RCCB, 4-pole, 40 A, 100 mA, Type A

MPN5SM3446-8

Siemens SENTRON selective RCCB, 4-pole, 40 A at 45 °C, 100 mA residual current, Type A, 10 kA SCCR, DIN rail mount, IP20.

Source DocumentedChannel stated on listing & quote
Condition PhotosReal unit photos / video on request
WhatsApp AnswersFast human replies for machine-down parts
Worldwide DispatchDHL/FedEx — transit quoted per order
Independent China distributor & sourcing agent· Listing updated Sep 2026

Specifications

5SM3446-8 — Electrical Ratings
ParameterValue
Number of poles4
Overvoltage categoryIII
5SM3446-8 — Identification
ParameterValue
Product designationRCCB
Product design / constructionSelective
5SM3446-8 — Mechanical
ParameterValue
Mounting positionany
Width in modular units4
Maximum45 °C
Minimum-25 °C
Width72 mm
Height90 mm
Depth77 mm
Installation depth70 mm
5SM3446-8 — Environmental
ParameterValue
IP degree of protectionIP20, if the distribution board is installed, with connected conductors
5SM3446-8 — Electrical
ParameterValue
Operational current / at AC / rated value63 A

Product details

Selective RCCB for 400 V AC feeder protection

The Siemens 5SM3446-8 is a 4-pole selective RCCB from the SENTRON series, rated at 40 A at both 40 °C and 45 °C ambient, with a 100 mA residual tripping current and Type A waveform sensitivity. Selective design means it introduces a deliberate time delay so that downstream RCCBs trip first, keeping this unit as the backup — critical for feeder coordination in a distribution board where you want the branch, not the main, to clear a ground fault.

Thermal derating and SCCR headroom

Rated 40 A up to 45 °C, then derates linearly to 28 A at 70 °C — a 30 % drop. Short-circuit current rating is 10 kA per IEC 61008-1, with an additional 0.8 kA rating under EN 60898. The 10 kA figure governs the upstream breaker coordination; the 0.8 kA is a conditional rating for the RCCB's own breaking capacity under standard test conditions.

Mounts in any position.

Frequently asked questions

What is the rated residual current of 5SM3446-8?

The tripping fault current is rated at 100 mA, Type A (sensitive to AC and pulsating DC residual currents).

What is the SCCR of 5SM3446-8?

The short-circuit current rating is 10 kA per IEC 61008-1, with an additional 0.8 kA rating under EN 60898.

Will 5SM3446-8 drop into a panel that was specified around 5SJ6325-7RC without rewiring?

Both are 4-pole DIN-rail RCCBs, but the 5SJ6325-7RC is a standard (non-selective) Type A unit; the 5SM3446-8 is selective with a time delay. Footprint is the same 4 MW width, but the selective delay changes coordination — verify the upstream breaker's time-current curve before swapping.

How do I get current pricing and availability for 5SM3446-8?

Submit an RFQ through the storefront. Pricing and stock are confirmed at quote time; the part is sourced to order through independent distribution.