Siemens 5SM3612-0MJ20 — Residual Current Breakers (RCCB/RCBO)

Siemens 5SM3612-0MJ20 SENTRON RCCB, 25 A, 300 mA, 2-pole

MPN5SM3612-0MJ20

Siemens SENTRON 5SM3 series, RCCB, 25 A, 300 mA, 230 V AC, 2-pole, DIN rail mount, IP20.

Source DocumentedChannel stated on listing & quote
Condition PhotosReal unit photos / video on request
WhatsApp AnswersFast human replies for machine-down parts
Worldwide DispatchDHL/FedEx — transit quoted per order
Independent China distributor & sourcing agent· Listing updated Sep 2026

Specifications

5SM3612-0MJ20 — Electrical Ratings
ParameterValue
Number of poles2
Overvoltage categoryIII
5SM3612-0MJ20 — Identification
ParameterValue
Product designationRCCB
Product design / constructionInstantaneous
5SM3612-0MJ20 — Mechanical
ParameterValue
Mounting positionany
Installation depth70 mm
5SM3612-0MJ20 — Environmental
ParameterValue
IP degree of protectionIP20, if the distribution board is installed, with connected conductors

Product details

The Siemens SENTRON 5SM3612-0MJ20 is a 2-pole residual current circuit breaker (RCCB) rated 25 A at 230 V AC, 50 Hz, with a 300 mA trip threshold and 10 kA short-circuit current rating. That's fine for general-purpose circuits feeding resistive or inductive loads like heaters, contactors, and small motors, but not for drives, UPS, or rectified loads where pulsating DC leakage would go undetected.

The 300 mA trip is a fire-protection threshold, not a personnel-protection level (that's 30 mA). You'd spec this on submain or feeder circuits where the leakage from multiple loads sums above 30 mA but below 300 mA — think lighting banks, distribution boards feeding socket outlets, or fixed equipment with high capacitive leakage. Conductor range accepts 1 to 16 mm² solid or stranded, so it'll take anything from a 1.5 mm² control wire up to a 16 mm² main feed. Mounts on DIN rail (REG profile), occupies 2 width units (about 36 mm), and can be installed in any orientation.

If the panel sits in a non-conditioned space that hits 50 °C in summer, you'll need to derate — but Siemens doesn't publish a derating curve for this RCCB, so keep it within the -5 to +45 °C band for full rated current.

Frequently asked questions

Where can I buy 5SM3612-0MJ20 and get current pricing?

This part is sourced and quoted to order against an RFQ through independent distribution. Availability and current pricing are confirmed at quote time — submit an RFQ for a firm price and lead time.

What conductor sizes does 5SM3612-0MJ20 accept?

It accepts 1 to 16 mm² solid or stranded conductors. The terminals are screw-type with a tightening torque of 2.5 to 3 N·m.

Will 5SM3612-0MJ20 drop into a panel wired for 5SU9304-1KK32?

Physically yes — both are 2-pole, DIN-rail mount, 70 mm installation depth, same width (2 width units). But the 5SU9304-1KK32 is a 32 A / 30 mA device, while this one is 25 A / 300 mA. If the circuit is designed for 32 A load or requires 30 mA personnel protection, this part won't work. Check the load current and trip requirement before swapping.

MPN
5SM3612-0MJ20