Skip to main content
Siemens 5SM3612-6BA — Residual Current Breakers (RCCB/RCBO)

Siemens 5SM3612-6BA SENTRON RCCB, 2-pole, 25 A, 300 mA, Type

MPN5SM3612-6BA

Siemens SENTRON 5SM3612-6BA, 2-pole RCCB, Type A, 25 A rated current, 300 mA residual, 230 V AC, 10 kA short-circuit rating, DIN rail mount.

Source DocumentedChannel stated on listing & quote
Condition PhotosReal unit photos / video on request
WhatsApp AnswersFast human replies for machine-down parts
Worldwide DispatchDHL/FedEx — transit quoted per order
Independent China distributor & sourcing agent· Listing updated Sep 2026

Specifications

5SM3612-6BA — Electrical Ratings
ParameterValue
Number of poles2
Overvoltage categoryIII
5SM3612-6BA — Identification
ParameterValue
Product designationRCCB
Product design / constructionInstantaneous
5SM3612-6BA — Mechanical
ParameterValue
Mounting positionany
Installation depth70 mm
5SM3612-6BA — Environmental
ParameterValue
IP degree of protectionIP20, if the distribution board is installed, with connected conductors

Product details

What it is and what the ratings mean

The Siemens SENTRON 5SM3612-6BA is a 2-pole RCCB from the 5SM3 design series, rated 25 A at 230 V AC with a 300 mA tripping residual current. Type A detects pulsating DC fault currents in addition to sinusoidal AC. The 10 kA short-circuit current rating (SCCR) at 230 V AC means the device can safely interrupt a fault current up to that level without welding contacts or rupturing the enclosure — a standard requirement for distribution boards fed from a transformer of typical impedance. Overvoltage category III confirms it is rated for fixed installation downstream of the main distribution board, not for outlet or appliance-level use.

Panel integration and wiring

Snaps onto DIN rail (REG profile) and occupies 2 width units. Installation depth is 70 mm. Screw terminals accept solid or stranded conductors from 1 to 16 mm². Tightening torque is 2.5 to 3 N·m. Supply can enter from top or bottom. Mounting position is any, and the housing is finger and back-of-hand safe (IP20 with conductors connected) — standard for enclosed distribution boards. The silicon-free construction matters if the panel is in a painting or coating environment where silicone outgassing can cause adhesion failures.

Frequently asked questions

What are the solid and stranded conductor ranges for 5SM3612-6BA?

The screw terminals accept solid conductors from 1 to 16 mm² and stranded conductors from 1 to 16 mm².

MPN
5SM3612-6BA