Skip to main content
Siemens 5SM3616-6KL — Residual Current Breakers (RCCB/RCBO)

Siemens 5SM3616-6KL SENTRON RCCB, 2-pole, 63 A, 300 mA, Type

MPN5SM3616-6KL

Siemens SENTRON 5SM3 series RCCB, 2-pole, Type A, 63 A rated current, 300 mA residual trip, 230 V AC, 10 kA short-circuit rating, DIN rail mount.

Source DocumentedChannel stated on listing & quote
Condition PhotosReal unit photos / video on request
WhatsApp AnswersFast human replies for machine-down parts
Worldwide DispatchDHL/FedEx — transit quoted per order
Independent China distributor & sourcing agent· Listing updated Sep 2026

Specifications

5SM3616-6KL — Electrical Ratings
ParameterValue
Number of poles2
Overvoltage categoryIII
5SM3616-6KL — Identification
ParameterValue
Product designationRCCB
Product design / constructionInstantaneous
5SM3616-6KL — Mechanical
ParameterValue
Mounting positionany
Width36 mm
Height90 mm
Depth70 mm
Installation depth70 mm
5SM3616-6KL — Environmental
ParameterValue
IP degree of protectionIP20, if the distribution board is installed, with connected conductors

Product details

The Siemens 5SM3616-6KL is a SENTRON 5SM3-series residual current circuit breaker (RCCB), 2-pole, Type A, rated 63 A at 230 V AC with a 300 mA residual trip threshold. It carries a 10 kA short-circuit current rating and is designed for instantaneous tripping — no short-time delay.

The 300 mA trip threshold is a delayed-action protection level typically used for fire prevention in circuits with high leakage from filters or long cable runs, not for direct personal shock protection (which requires 30 mA or lower). This matches the typical prospective short-circuit current at the service entrance of most European residential and light-commercial panels. The 63 A rated current and 2-pole configuration suit it for a single-phase 230 V feeder or submain — for example, a large lighting circuit, a small distribution board, or a high-power appliance feed. The 2.5-module width (36 mm) on DIN rail means it occupies two and a half 18 mm slots, so factor that into panel fill calculations.

Mounts on DIN rail (REG) in any position. The 70 mm installation depth matches standard 70 mm deep enclosures — no need for a deeper gland plate. Terminals accept solid or stranded conductors from 1.5 to 25 mm²; tighten to 2.5–3 N·m with a screwdriver. IP20 with connected conductors, so it requires enclosure protection against moisture and dust. The device is silicon-free.

Frequently asked questions

How do I get current pricing and availability for 5SM3616-6KL?

Submit an RFQ through this listing. The part is sourced to order via independent distribution; pricing and stock levels are confirmed at quote time.

Will 5SM3616-6KL drop into a panel that was specified around 5SU9354-8KK63 without rewiring?

Both are 2-pole RCCBs on DIN rail with similar terminal ranges, but the 5SM3616-6KL is a 63 A / 300 mA Type A device while the 5SU9354-8KK63 is a different rating. Verify the required current and residual trip before substitution — the footprint and wiring method are compatible, but the protection parameters must match the circuit design.

What compliance documentation does this brand provide for 5SM3616-6KL (RoHS, REACH, UL, IEC)?

The device carries the SENTRON brand and is designed to IEC/EN 61008-1 (RCCB standard). The evidence does not list specific UL, RoHS, or REACH certificates, but as a current-production Siemens catalog item, standard compliance declarations are available from the manufacturer upon request.

MPN
5SM3616-6KL