Skip to main content
Siemens 5SM3616-6KL01 — Residual Current Breakers (RCCB/RCBO)

Siemens 5SM3616-6KL01 SENTRON RCCB, 63 A, 300 mA, 2-pole

MPN5SM3616-6KL01

Siemens SENTRON 5SM3 series RCCB, 2-pole, Type A, short-time delayed, 63 A rated, 300 mA trip, 230 V AC, 50 Hz, DIN rail mount.

Source DocumentedChannel stated on listing & quote
Condition PhotosReal unit photos / video on request
WhatsApp AnswersFast human replies for machine-down parts
Worldwide DispatchDHL/FedEx — transit quoted per order
Independent China distributor & sourcing agent· Listing updated Sep 2026

Specifications

5SM3616-6KL01 — Electrical Ratings
ParameterValue
Number of poles2
Overvoltage categoryIII
5SM3616-6KL01 — Identification
ParameterValue
Product designationRCCB
Product design / constructionShort-time delayed
5SM3616-6KL01 — Mechanical
ParameterValue
Mounting positionany
Width36 mm
Height90 mm
Depth70 mm
Installation depth70 mm
5SM3616-6KL01 — Environmental
ParameterValue
IP degree of protectionIP20, if the distribution board is installed, with connected conductors

Product details

The Siemens 5SM3616-6KL01 is a 2-pole residual current circuit breaker (RCCB) from the SENTRON 5SM3 series, rated 63 A at 230 V AC, 50 Hz, with a 300 mA trip threshold and Type A fault current sensitivity. The short-time delayed design means it tolerates brief surge currents up to 3 kA without nuisance tripping — useful on circuits with motor drives or switching power supplies that generate a short inrush.

Mounts on DIN rail (REG) and occupies 2.5 width units (36 mm wide, 90 mm high, 70 mm deep). The screw terminals accept solid or stranded copper from 1.5 to 25 mm²; tighten to 2.5–3 N·m. Supply can land top or bottom. The N-left variant places the neutral on the left side — check your busbar orientation before wiring. IP20 with the distribution board closed and conductors connected; not rated for wet or washdown environments.

Frequently asked questions

Where can I buy 5SM3616-6KL01 and how do I get a price?

Sourced and quoted to order against an RFQ through independent distribution; availability and current pricing are confirmed at quote time.

What is 5SM3616-6KL01's listed depth?

The installation depth is 70 mm.

What wire sizes does 5SM3616-6KL01 accept?

The screw terminals accept solid or stranded copper from 1.5 to 25 mm².

What does Type A fault current mean on this RCCB?

Type A detects sinusoidal AC and pulsating DC fault currents, covering most modern electronic loads like rectifiers and switching power supplies.

MPN
5SM3616-6KL01