Skip to main content
Siemens 5SM3626-4KK14 — Residual Current Breakers (RCCB/RCBO)

Siemens SENTRON 5SM3626-4KK14 RCCB, 63 A, 230 V, B+ Type

MPN5SM3626-4KK14

Siemens SENTRON 5SM3 series RCCB, 2-pole, 63 A at 40 °C, 230 V AC, B+ fault current type, short-time delayed, 10 kA short-circuit current rating, DIN rail mounting, IP20.

Source DocumentedChannel stated on listing & quote
Condition PhotosReal unit photos / video on request
WhatsApp AnswersFast human replies for machine-down parts
Worldwide DispatchDHL/FedEx — transit quoted per order
Independent China distributor & sourcing agent· Listing updated Sep 2026

Specifications

5SM3626-4KK14 — Electrical Ratings
ParameterValue
Number of poles2
Overvoltage categoryIII
5SM3626-4KK14 — Identification
ParameterValue
Product designationRCCB
Product design / constructionShort-time delayed
5SM3626-4KK14 — Mechanical
ParameterValue
Mounting positionany
Maximum45 °C
Minimum-25 °C
Width72 mm
Height90 mm
Depth70 mm
Installation depth70 mm
5SM3626-4KK14 — Environmental
ParameterValue
IP degree of protectionIP20, if the distribution board is installed, with connected conductors

Product details

The Siemens SENTRON 5SM3626-4KK14 is a 2-pole residual current circuit breaker (RCCB) rated 63 A at 40 °C and 230 V AC, with a B+ fault current type and short-time delayed switching function. The 63 A rating at 40 °C is the continuous current it carries in a panel at that ambient — at 70 °C it still holds 50.4 A, so the thermal derating curve is real and worth checking if your enclosure runs hot near the kiln or furnace line. The B+ type detects AC, pulsating DC, smooth DC, and high-frequency fault currents up to 1 kHz, which covers variable-speed drive leakage and modern power supply earth faults that a standard AC type would miss. The short-time delayed design (S-type) means it withstands transient leakage pulses up to 3 kA surge current without tripping, giving selectivity with downstream instantaneous RCCBs — essential for a distribution board feeding multiple sub-circuits. IP20 with conductors connected, finger and back-of-hand safe per the protection class.

Integration and mounting notes

Mounting position is any orientation. The supply cord can enter from the top or bottom — bottom entry also powers the SIGRES function in the switched-off state. Installation depth is 70 mm, matching the device depth. The 4 width units (72 mm) occupy four 18 mm module spaces in a distribution board. Silicon-free construction, suitable for environments where silicone outgassing could contaminate contacts or optics.

Thermal derating across ambient temperature

Rated current is 63 A at both 40 °C and 45 °C ambient. At 50 °C it derates to 60.5 A, at 55 °C to 58 A, at 60 °C to 55.4 A, at 65 °C to 52.9 A, and at 70 °C to 50.4 A.

Frequently asked questions

Who supplies 5SM3626-4KK14 and how is it quoted?

Sourced and quoted to order against an RFQ through independent distribution channels. Submit an RFQ for current pricing and availability.

What are the key ratings of 5SM3626-4KK14?

63 A at 40 °C, 230 V AC, B+ fault current type, short-time delayed, 10 kA SCCR, 3 kA surge current resistance, 2-pole, DIN rail mount, IP20.

What is the difference between this B+ type RCCB and a standard AC type?

The B+ type detects AC, pulsating DC, smooth DC, and high-frequency fault currents up to 1 kHz, covering VFD leakage and modern power supply earth faults that a standard AC-only RCCB would miss.

MPN
5SM3626-4KK14