Siemens 5SM3646-5 — Residual Current Breakers (RCCB/RCBO)

Siemens 5SM3646-5 SENTRON RCCB, 63A 4P Type B Selective, 300

MPN5SM3646-5

Siemens SENTRON 5SM3646-5, selective Type B RCCB, 4-pole, 63 A, 300 mA residual current, 10 kA SCCR, DIN rail mount.

Source DocumentedChannel stated on listing & quote
Condition PhotosReal unit photos / video on request
WhatsApp AnswersFast human replies for machine-down parts
Worldwide DispatchDHL/FedEx — transit quoted per order
Independent China distributor & sourcing agent· Listing updated Sep 2026

Specifications

5SM3646-5 — Electrical Ratings
ParameterValue
Number of poles4
Overvoltage categoryIII
5SM3646-5 — Identification
ParameterValue
Product designationRCCB
Product design / constructionSelective
5SM3646-5 — Mechanical
ParameterValue
Mounting positionany
Width in modular units4
Maximum45 °C
Minimum-25 °C
Width72 mm
Height90 mm
Depth77 mm
Installation depth70 mm
5SM3646-5 — Environmental
ParameterValue
IP degree of protectionIP20, if the distribution board is installed, with connected conductors

Product details

The Siemens SENTRON 5SM3646-5 is a selective Type B residual current circuit breaker (RCCB) — 4-pole, rated 63 A at 40 °C, with a 300 mA tripping threshold and a 10 kA short-circuit current rating. The selective design (time-delayed) means it coordinates with downstream RCCBs: on a fault, the downstream device trips first, leaving this one closed to keep upstream circuits live. That's the difference between losing one branch and losing the whole panel.

Type B detection handles AC, pulsating DC, smooth DC, and high-frequency residual currents. The 300 mA trip threshold is typical for selective RCCBs in distribution boards feeding sub-distribution or fixed equipment. At 50 °C it drops to 60.48 A, at 60 °C to 55.44 A, and at 70 °C to 50.4 A. The EN 60898 rating is 0.8 kA — that's the lower conditional rating under that standard's test sequence, not the interrupting capacity you design to. Use the 10 kA figure for your SCCR label.

Panel integration

Mounting position is any — no restriction on upright or horizontal. The top or bottom feed option means you can bus it either way; the SIGRES function (selective isolation) stays active even with bottom feed in the off state. Silicon-free construction, which matters if this goes into a paint shop or coating line where silicone outgassing causes fisheyes.

Frequently asked questions

What is the 5SM3646-5 used for?

It's a selective (time-delayed) Type B RCCB for distribution boards where you need earth-fault discrimination between the main switch and downstream RCCBs. Typical applications include sub-distribution feeding VFD-driven loads, UPS systems, or medical equipment that generates smooth DC fault currents.