Siemens 5SM3646-5KK14 — Residual Current Breakers (RCCB/RCBO)

Siemens SENTRON 5SM3646-5KK14 RCCB, 4P, 63 A, 300 mA, Type B

MPN5SM3646-5KK14

Siemens SENTRON series, selective RCCB, 4-pole, 63 A at 40 °C, 300 mA residual, Type B+, 10 kA SCCR, DIN rail mount.

Source DocumentedChannel stated on listing & quote
Condition PhotosReal unit photos / video on request
WhatsApp AnswersFast human replies for machine-down parts
Worldwide DispatchDHL/FedEx — transit quoted per order
Independent China distributor & sourcing agent· Listing updated Sep 2026

Specifications

5SM3646-5KK14 — Electrical Ratings
ParameterValue
Number of poles4
Overvoltage categoryIII
5SM3646-5KK14 — Identification
ParameterValue
Product designationRCCB
Product design / constructionSelective
5SM3646-5KK14 — Mechanical
ParameterValue
Mounting positionany
Width in modular units4
Maximum45 °C
Minimum-25 °C
Width72 mm
Height90 mm
Depth77 mm
Installation depth70 mm
5SM3646-5KK14 — Environmental
ParameterValue
IP degree of protectionIP20, if the distribution board is installed, with connected conductors

Product details

The Siemens SENTRON 5SM3646-5KK14 is a 4-pole selective residual current circuit breaker (RCCB) rated for 63 A at 40 °C with a 300 mA residual trip threshold. The Type B+ characteristic means it detects AC, pulsating DC, smooth DC, and high-frequency residual currents — covering VFD-fed loads, UPS systems, and EV charging circuits where standard Type A or AC devices would be blind to DC fault components. The selective (time-delayed) design coordinates with downstream 30 mA RCCBs so that only the faulted branch trips, keeping the rest of the distribution board live. Rated short-circuit current withstand is 10 kA, with an additional rating of 0.8 kA per EN 60898 and IEC 61008-1.

Integration notes

Panel integration is straightforward: the 77 mm depth and 72 mm width fit standard DIN-rail enclosures with 4 module spaces. Installation depth of 70 mm leaves clearance for wiring behind the rail. The device is silicon-free — relevant for potting or conformal-coating processes in vibration-prone or humid environments. The temperature derating curve is published: full 63 A up to 45 °C, then 60.5 A at 50 °C, 58 A at 55 °C, 55.4 A at 60 °C, 52.9 A at 65 °C, and 50.4 A at 70 °C. The permissible I²t value of 70,000 A²·s and let-through current of 7,500 kA are coordination values for the upstream MCB or fuse — keep those figures handy for the selective coordination study.

Frequently asked questions

Where can I buy 5SM3646-5KK14?

This part is sourced and quoted to order against an RFQ through independent distribution. Availability and current pricing are confirmed at quote time — submit an RFQ for a firm position.

What does Type B+ mean on this RCCB?

Type B+ detects AC, pulsating DC, smooth DC, and high-frequency residual currents up to 1 kHz. It's specified for applications with VFDs, UPS systems, EV chargers, and other loads that generate DC fault components a standard Type A device would miss.

What is the difference between this 5SM3646-5KK14 and a standard 5SL4 series RCCB?

The 5SM3646-5KK14 is a selective (time-delayed) Type B+ device rated 63 A / 300 mA. A standard 5SL4 RCCB is typically a non-selective Type A or AC device at lower current ratings. The selective design allows this unit to coordinate with downstream 30 mA RCCBs so only the faulted branch trips — a 5SL4 would trip immediately on any residual fault, taking the whole submain down.