Siemens 5SM3647-5KK14 — Residual Current Breakers (RCCB/RCBO)

Siemens SENTRON 5SM3647-5KK14 RCCB, 4-pole, 80 A, 300 mA, Ty

MPN5SM3647-5KK14

Siemens SENTRON selective RCCB, 5SM3647-5KK14, 4-pole, 80 A rated at 40 °C, 300 mA trip, Type B+, 10 kA SCCR, 400 V AC, 4 MW DIN rail.

Source DocumentedChannel stated on listing & quote
Condition PhotosReal unit photos / video on request
WhatsApp AnswersFast human replies for machine-down parts
Worldwide DispatchDHL/FedEx — transit quoted per order
Independent China distributor & sourcing agent· Listing updated Sep 2026

Specifications

5SM3647-5KK14 — Electrical Ratings
ParameterValue
Number of poles4
Overvoltage categoryIII
5SM3647-5KK14 — Identification
ParameterValue
Product designationRCCB
Product design / constructionSelective
5SM3647-5KK14 — Mechanical
ParameterValue
Mounting positionany
Width in modular units4
Maximum45 °C
Minimum-25 °C
Width72 mm
Height90 mm
Depth77 mm
Installation depth70 mm
5SM3647-5KK14 — Environmental
ParameterValue
IP degree of protectionIP20, if the distribution board is installed, with connected conductors

Product details

The Siemens SENTRON 5SM3647-5KK14 is a selective residual current circuit breaker (RCCB) — 4-pole, rated 80 A at 40 °C, with a 300 mA trip threshold and Type B+ residual current sensitivity. The selective design (short-time delayed) means it coordinates with downstream RCCBs so only the faulted circuit trips, keeping the rest of the installation live.

At 50 °C it's still 76.8 A, at 60 °C it's 70.4 A, and at 70 °C it's 64 A. If your panel runs hot, use the 50 °C or 60 °C row for sizing, not the 40 °C headline. Type B+ detects smooth DC residual currents up to the rated frequency, plus AC and pulsed DC — covers VFDs, UPS systems, and EV chargers where pure AC-sensitive RCCBs would be blind. The 300 mA trip level is typical for sub-distribution or final circuits where 30 mA would nuisance-trip on leakage from filters or drives. Short-circuit withstand is 10 kA per IEC 61008-1 and EN 60898 (0.8 kA rated conditional). The let-through current is capped at 7 500 A, and the I²t value is 70 000 A²·s — useful for coordination with upstream MCBs or fuses.

The 72 mm width (4 MW) matches standard Siemens SENTRON modular devices — rows line up without adapters. IP20 with conductors connected and distribution board installed; not for wet locations. Silicon-free construction — important for automotive paint shops or semiconductor fabs where silicone outgassing can cause adhesion or contamination issues.

Frequently asked questions

What is the closest functional second-source for 5SM3647-5KK14?

The peer MPNs listed (5SL4363-7, 5SJ6325-7RC, 5SY4304-7CV) are from the same SENTRON family but differ in pole count, trip current, or type — they are not drop-in replacements. The 5SM3647-5KK14 is a 4-pole, 80 A, 300 mA, Type B+ selective RCCB; verify ratings before substituting.

MPN