Siemens 5SM3647-6KK01 — Residual Current Breakers (RCCB/RCBO)

Siemens 5SM3647-6KK01 SENTRON RCCB, 4P, Type A, 80 A, 300 mA

MPN5SM3647-6KK01

Siemens SENTRON 5SM3647-6KK01, 4-pole RCCB, type A, short-time delayed, In 80 A, IΔn 300 mA, Un AC 400 V, DIN rail mount.

Source DocumentedChannel stated on listing & quote
Condition PhotosReal unit photos / video on request
WhatsApp AnswersFast human replies for machine-down parts
Worldwide DispatchDHL/FedEx — transit quoted per order
Independent China distributor & sourcing agent· Listing updated Sep 2026

Specifications

5SM3647-6KK01 — Electrical Ratings
ParameterValue
Number of poles4
Overvoltage categoryIII
5SM3647-6KK01 — Identification
ParameterValue
Product designationRCCB
Product design / constructionShort-time delayed
5SM3647-6KK01 — Mechanical
ParameterValue
Mounting positionany
Width72 mm
Height90 mm
Depth77 mm
Installation depth70 mm
5SM3647-6KK01 — Environmental
ParameterValue
IP degree of protectionIP20, if the distribution board is installed, with connected conductors

Product details

The 5SM3647-6KK01: The 80 A rated current and 300 mA residual trip define the load and protection envelope. The 300 mA rating is a deliberate choice for circuits with high leakage from equipment filters or long cable runs — it avoids nuisance tripping that a 30 mA device would cause. The short-time delayed design (type A, short-time delayed) means it withstands surge currents up to 3 kA without tripping, so it coordinates with upstream overcurrent devices and handles inrush from motor drives or UPS systems without dropping the line. Type A detection catches both sinusoidal AC residual currents and pulsating DC fault currents, which covers most modern electronic loads — switched-mode power supplies, variable-speed drives, and rectifier circuits.

Snaps onto DIN rail (REG profile). The screw-type terminals accept solid or stranded conductors from 1.5 mm² up to 25 mm², and the tightening torque range is 2.5 to 3 N·m.

Frequently asked questions

What is the 5SM3647-6KK01 used for?

It's a 4-pole residual current circuit breaker (RCCB) type A, short-time delayed, rated 80 A / 300 mA / 400 V. It protects circuits against earth faults, including pulsating DC from electronic loads, while the 300 mA trip and short-time delay prevent nuisance tripping on circuits with high leakage or surge currents.

Where can I buy the 5SM3647-6KK01?

This part is sourced and quoted to order against an RFQ through independent distribution. Availability and current pricing are confirmed at quote time — submit an RFQ for a firm price and lead time.

Will the 5SM3647-6KK01 drop into a panel designed for a 5SY4304-7CV?

Not without rewiring. The 5SM3647-6KK01 is a 4-pole RCCB (77 mm deep, 72 mm wide, 4 width units), while the 5SY4304-7CV is a 3-pole MCB (76 mm deep, 54 mm wide, 3 width units). Different function, different pole count, different footprint — they are not drop-in replacements.

MPN
5SM3647-6KK01