Skip to main content
Siemens 5SM3745-6 — Residual Current Breakers (RCCB/RCBO)

Siemens 5SM3745-6 SENTRON RCCB, 4P, 125 A, 500 mA, Type A

MPN5SM3745-6

Siemens SENTRON RCCB, 4-pole, 125 A, 500 mA trip, Type A, 10 kA SCCR, 400 V AC, 50 Hz, DIN rail mount, IP20.

$707.39Ref. price · indicative, final on quote
StockContact for availability
MOQ1 pcs
Sourced new & surplus through independent channelsListing updated Jul 2026

Specifications

Electrical Ratings

5SM3745-6 — Electrical Ratings
ParameterValue
Number of poles4
Overvoltage categoryIII

Identification

5SM3745-6 — Identification
ParameterValue
Product designationRCCB
Product design / constructionInstantaneous

Mechanical

5SM3745-6 — Mechanical
ParameterValue
Mounting positionany
Width in modular units4
Maximum45 °C
Minimum-25 °C
Width72 mm
Height90 mm
Depth77 mm
Installation depth70 mm

Environmental

5SM3745-6 — Environmental
ParameterValue
IP degree of protectionIP20, if the distribution board is installed, with connected conductors

Product details

Siemens 5SM3745-6 SENTRON RCCB — 4-pole, 125 A, Type A, instantaneous

The Siemens 5SM3745-6 is a 4-pole SENTRON residual current circuit breaker (RCCB) rated for 125 A at 400 V AC, 50 Hz. It trips on a 500 mA residual current and is designed as an instantaneous (short-time-delayed: No) Type A device, meaning it detects sinusoidal AC and pulsating DC fault currents — the standard for mixed-load panels with electronics, VFDs, or rectified supplies. The 4-module-width body (72 mm) snaps onto DIN rail (REG) and can be mounted in any orientation. IP20 with conductors connected — suitable for enclosed distribution boards, not for wet-area standalone use.

Rated current and thermal derating

Full 125 A rating holds up to 45 °C ambient. Above that, derate linearly: 120 A at 50 °C, 115 A at 55 °C, 110 A at 60 °C, 105 A at 65 °C, 100 A at 70 °C. If the panel ambient runs near 50 °C, the 125 A frame still carries 120 A continuous — no need to oversize for a warm cabinet unless you exceed 70 °C.

Fault current withstand and selectivity

Short-circuit current rating (SCCR) is 10 kA per IEC 61008-1, with a let-through current of 8 000 A and a permissible I²t of 94 000 A²·s. For coordination with an upstream MCB, the conditional rating per EN 60898 is 1.25 kA — this is the value to use when the RCCB is backed by a 10 kA MCB in a standard final-distribution board. Surge-current resistance is 1 kA (8/20 µs), so it holds against lightning-induced transients without nuisance tripping.

Frequently asked questions

What are the key ratings of the 5SM3745-6?

4-pole RCCB, 125 A rated current at 400 V AC, 50 Hz, 500 mA residual trip current, Type A (sinusoidal + pulsating DC detection), instantaneous switching, 10 kA SCCR per IEC 61008-1, DIN rail mount, IP20.

What is the depth of the 5SM3745-6?

77 mm body depth, with an installation depth of 70 mm behind the panel face.

What is the width of the 5SM3745-6?

72 mm, which corresponds to 4 modular-width units on a standard DIN-rail profile.

Where can I buy the 5SM3745-6 and get current pricing?

Sourced and quoted to order against an RFQ through independent distribution. Availability and current pricing are confirmed at quote time — submit an RFQ for a firm commercial offer.

MPN
5SM3745-6