Skip to main content
Siemens 5SM6011-1XX01 — Residual Current Breakers (RCCB/RCBO)

Siemens SENTRON 5SM6011-1XX01 Arc-Fault Detection Unit, 16A,

MPN5SM6011-1XX01

Siemens SENTRON arc-fault detection unit, pre-assembled with MCB 1+N B16, 16 A rated current, 230 V AC, 6 kA breaking capacity, 2-module width, DIN rail mount.

Sourced new & surplus through independent channelsAuthenticity-screened · ESD-safe packingListing updated Jul 2026

Specifications

5SM6011-1XX01 — Electrical Ratings
ParameterValue
Number of poles2
Overvoltage categoryIII
5SM6011-1XX01 — Identification
ParameterValue
Product designationArc-fault detection unit
Product design / constructionpre-assembled with MCB 1+N B16
5SM6011-1XX01 — Mechanical
ParameterValue
Mounting positionany
Width in modular units2
Maximum75 °C
Minimum-40 °C
Width36 mm
Height95 mm
Depth68.5 mm
Installation depth70 mm
5SM6011-1XX01 — Environmental
ParameterValue
IP degree of protectionIP20, with connected protective device and conductors
5SM6011-1XX01 — Electrical
ParameterValue
Operational current / at AC / rated value16 A

Product details

The Siemens SENTRON 5SM6011-1XX01 is a pre-assembled arc-fault detection device (AFDD) with an integrated miniature circuit breaker (MCB) 1+N B16, designed to detect and interrupt dangerous series and parallel arcs in final circuits. Rated at 16 A operational current on 230 V AC (50 Hz), it combines arc-fault detection with overcurrent and short-circuit protection in a single 2-module-wide (36 mm) DIN-rail housing — a space-saving fit for residential and light-commercial distribution boards.

Arc detection range — what it catches and what it passes

Series arc detection covers 2 A to 16 A; parallel arc detection covers 50 A to 500 A. That means it catches low-energy arcs in series with the load (e.g., a loose terminal on a 2 A lighting circuit) and high-energy arcs between line and neutral or line and earth up to 500 A. The 2 A minimum series-arc threshold is notable — it protects circuits where a bad connection might draw well below the MCB's magnetic trip threshold, which is exactly the kind of fault a standard breaker alone won't catch.

Integration notes

Mounts on DIN rail (REG) in any position. Installation depth 70 mm; device 68.5 mm deep, 36 mm wide, 95 mm tall. Degree of pollution 2, overvoltage category III — suitable for fixed-installation distribution boards in dry or intermittently humid environments. Halogen-free and silicon-free. Mechanical service life 10,000 switching cycles typical.

MPN
5SM6011-1XX01