Siemens 5SM9322-6KN — Residual Current Breakers (RCCB/RCBO)

Siemens 5SM9322-6KN SENTRON RC Unit, 2-Pole, 40 A, 30 mA Typ

MPN5SM9322-6KN

Siemens SENTRON RC unit electronic, 5SM9322-6KN, 2-pole, Type A, 40 A rated, 30 mA trip, 230 V AC, 50 Hz, instantaneous.

Sourced new & surplus through independent channelsAuthenticity-screened · ESD-safe packingListing updated Aug 2026

Specifications

5SM9322-6KN — Electrical Ratings
ParameterValue
Number of poles2
5SM9322-6KN — Identification
ParameterValue
Product designationRC unit electronic
Product design / constructionInstantaneous
5SM9322-6KN — Other specifications
ParameterValue
At AC rated value40 A
Residual current typeA
Tripping fault current rated value30 mA
Value range of the supply voltage at AC230 V
Value range of the supply voltage frequency50 Hz
For rated value of the current at AC in hot operating state per pole0.8 W

Product details

The Siemens 5SM9322-6KN is a SENTRON RC unit electronic, a 2-pole residual current device (RCD) with a 40 A rated current and a 30 mA tripping threshold, Type A, for 230 V AC at 50 Hz. The instantaneous design means it trips with no intentional delay, so it's the right choice where fast disconnection is needed — typically on final circuits supplying socket outlets or handheld equipment.

The 2-pole form factor snaps onto a DIN rail inside the distribution board. Rated 40 A continuous, it feeds directly from a 40 A upstream MCB or as a standalone RCD for a subcircuit. The 30 mA trip level provides additional fire and personnel protection on socket-outlet circuits. Power dissipation is 0.8 W per pole in the hot operating state, so thermal buildup in a crowded enclosure stays manageable — no forced cooling needed for normal residential or light commercial panels.

The 40 A rating means this RC unit can carry a 40 A load continuously without overheating, matching a 40 A MCB upstream for full selectivity. Type A detection handles the pulsed DC from rectified circuits (computers, LED drivers, variable-speed drives), so it's not limited to purely sinusoidal faults. The 230 V AC, 50 Hz supply voltage is the standard single-phase European residential and light commercial mains.

Frequently asked questions

What is the rated current and trip sensitivity of 5SM9322-6KN?

The unit is rated 40 A continuous with a 30 mA residual trip current, Type A, instantaneous, for 230 V AC 50 Hz supply.

Where can I buy 5SM9322-6KN?

This part is sourced and quoted to order against an RFQ through independent distribution. Availability and current pricing are confirmed at quote time.

What is the number of poles on 5SM9322-6KN?

It is a 2-pole device, switching both line and neutral on a single-phase circuit.