Siemens 5SM9325-0KN — Residual Current Breakers (RCCB/RCBO)

SENTRON 5SM9325-0KN RC Unit, 2-Pole, 63 A, 30 mA, 230 V AC

MPN5SM9325-0KN

SENTRON 5SM9325-0KN RC unit electronic, 2-pole, type AC, In: 63 A, 30 mA, Un AC: 230 V, 50 Hz, instantaneous design.

Sourced new & surplus through independent channelsAuthenticity-screened · ESD-safe packingListing updated Aug 2026

Specifications

5SM9325-0KN — Electrical Ratings
ParameterValue
Number of poles2
5SM9325-0KN — Identification
ParameterValue
Product designationRC unit electronic
Product design / constructionInstantaneous
5SM9325-0KN — Other specifications
ParameterValue
Rated value50 Hz
At AC230 V
Type of fault currentAC
Circuit-breaker (Design)5SM9
Current (at AC)63 A
Tripping residual current30 mA

Product details

The SENTRON 5SM9325-0KN is a 2-pole residual current unit (RC unit electronic) rated for 63 A at 230 V AC, 50 Hz, with a 30 mA tripping threshold for AC fault currents. Its instantaneous design means it trips without intentional delay when the residual current exceeds 30 mA — no time-grading for selectivity, so it's a straightforward fit for branch circuits where fast disconnection is the priority, not coordination with downstream RCDs.

The 63 A rating covers the full incoming supply for a sub-distribution board or a high-load single-phase circuit — most domestic RCDs top out at 40 A or 63 A, so this sits at the upper end. Type AC means it detects sinusoidal AC residual currents only; if the downstream load includes electronics, variable-speed drives, or rectifiers that generate pulsed DC fault currents, a Type A or Type F unit would be needed instead.

Panel integration

Width is two modular units (36 mm), leaving adjacent slots for the upstream MCB or main switch. No neutral bar required — the unit switches the neutral internally.

Frequently asked questions

Where can I buy 5SM9325-0KN and how is it quoted?

This part is sourced and quoted to order against an RFQ through independent distribution channels. Availability and current pricing are confirmed at quote time — submit an RFQ for a firm price and lead time.

What does the 30 mA trip rating mean for installation?

30 mA is the standard threshold for additional protection against direct contact in final circuits per IEC 60364. It provides personal shock protection while avoiding nuisance tripping on normal leakage from fixed appliances.

Will 5SM9325-0KN drop into a panel specified for 5SQ2670-2YA63?

No — 5SQ2670-2YA63 is a 4-pole RCBO (overcurrent + residual) with a C-curve MCB and 400 V rating, while 5SM9325-0KN is a 2-pole standalone RCD at 230 V. They are not footprint- or function-interchangeable without rewiring the panel.