Siemens 5SM9425-0KK SENTRON RC Unit, 2-Pole, 63 A, 100 mA, 4

MPN5SM9425-0KK

Siemens SENTRON 5SM9 series, RC unit electronic, instantaneous design, 2-pole, type AC, In: 63 A, IΔn: 100 mA, Un AC: 230/400 V, 50 Hz.

StockContact for availability
MOQ1 pcs
Sourced new & surplus through independent channelsListing updated Jul 2026

Specifications

Electrical Ratings

5SM9425-0KK — Electrical Ratings
ParameterValue
Number of poles2

Identification

5SM9425-0KK — Identification
ParameterValue
Product designationRC unit electronic
Product design / constructionInstantaneous

Product details

The Siemens 5SM9425-0KK is a SENTRON residual current (RC) unit — a 2-pole, type AC device rated for 63 A continuous at 230/400 V AC, 50 Hz, with a 100 mA tripping threshold. It's an instantaneous electronic RC unit, meaning no intentional time delay; it trips as soon as the residual current exceeds 100 mA. At 40 °C and 45 °C it carries the full 58.59 A without derating; from 50 °C upward the current capacity steps down gradually to 50.4 A at 70 °C.

What the ratings mean for fit

The 63 A rating governs the load it can pass continuously in a 40 °C ambient — sized for a submain or a large final circuit. The 100 mA residual sensitivity is less common than the standard 30 mA (personnel protection); 100 mA is typically specified for equipment protection or where nuisance tripping from leakage on long cable runs is a concern. Type AC means it detects sinusoidal AC residual currents only — not pulsed DC or smooth DC, so it's suited for conventional resistive and inductive AC loads, not VFDs, UPS systems, or EV chargers that generate DC fault components. The 2-pole construction (switching both phase and neutral) fits single-phase or split-phase panels where the neutral must be interrupted. Mounts on standard DIN rail in any position, occupying 2 width units (36 mm).

Frequently asked questions

Where can I buy 5SM9425-0KK and how do I get a price?

This part is sourced and quoted to order against an RFQ through independent distribution. Availability and current pricing are confirmed at quote time — submit an RFQ for a firm price and lead time.

What is 5SM9425-0KK's rated current at 40 °C?

At 40 °C the part carries 58.59 A. The same 58.59 A holds at 45 °C; above that it derates stepwise to 50.4 A at 70 °C.

Will 5SM9425-0KK drop into a panel that was specified around 5SJ3140-7 without rewiring?

No — these are different device classes. The 5SJ3140-7 is a 1-pole miniature circuit breaker (MCB) with a 40 A rating and C-curve trip characteristic. The 5SM9425-0KK is a 2-pole residual current unit with 63 A rating and 100 mA trip threshold. They serve different functions (overcurrent protection vs. earth leakage protection) and occupy different DIN positions. A panel specified for the MCB would need additional wiring and space for the RC unit.