Skip to main content
Siemens 5SN4350-7CN — 3-Pole MCB (DIN Rail)

Siemens 5SN4350-7CN SENTRON MCB, 3P C 50A 10kA 400V

MPN5SN4350-7CN

Siemens SENTRON 5SN4350-7CN, miniature circuit breaker, 3-pole, C characteristic, 50 A, 10 kA per EN 60898 at 400 V AC, 3 modular width units.

StockContact for availability
MOQ1 pcs
Sourced new & surplus through independent channelsListing updated Jul 2026

Specifications

Identification

5SN4350-7CN — Identification
ParameterValue
Brand nameSENTRON
Number of poles3
Pole configuration3P

Protection

5SN4350-7CN — Protection
ParameterValue
Tripping characteristic (curve)C
Breaking capacity per EN 6089810 kA
Overvoltage categoryIII
IP protection classIP20, with connected conductors
Energy limitation class3
Pollution degree2

Electrical

5SN4350-7CN — Electrical
ParameterValue
Rated voltage (AC, multi-phase)440 V
Voltage type (AC/DC)AC
Supply frequency range50/60 Hz
Power loss per pole at rated current (AC, hot)3.6 W

Mechanical

5SN4350-7CN — Mechanical
ParameterValue
Modular width units3
Mounting positionany
Width54 mm
Height90 mm
Depth76 mm
Installation depth70 mm
Terminal tightening torque, max.75 °C
Terminal tightening torque, min.-40 °C
SealableYes
Accepts supplementary devicesYes

Environmental

5SN4350-7CN — Environmental
ParameterValue
Halogen-freeYes
Silicone-freeYes
Influence of surrounding temperature+55 °C, max. 95% humidity
Vibration resistance (IEC 60068-2-6)50 m/s² at 25 to 150 Hz

Product details

The Siemens SENTRON 5SN4350-7CN is a 3-pole miniature circuit breaker with a C tripping characteristic, rated 50 A and 400 V AC. Its 10 kA breaking capacity per EN 60898 covers the majority of commercial and light industrial panel applications where fault levels stay under that threshold. The C-curve means it tolerates moderate inrush — think motor starters, banks of LED drivers, or small transformer primaries — without nuisance tripping, while still clearing fast on a hard short.

Fit and panel integration

At 54 mm wide (3 modular width units) and 76 mm deep, it occupies standard DIN-rail space. The 70 mm installation depth leaves room behind a 100 mm deep enclosure for wiring. Solid conductors up to 25 mm² land on the terminals — enough for a 50 A feed on a sub-main or feeder breaker. Mounting position is unrestricted, so it works in vertical or horizontal panel layouts without derating the thermal trip. IP20 with connected conductors means it's intended for enclosed panels only — no exposed installation. The sealable design lets a panel builder or inspector lock the breaker in the OFF position for lockout/tagout compliance.

Environmental range and materials

Rated for ambient temperatures from -40 °C to +75 °C, with a derating influence noted at +55 °C and 95% humidity. Halogen-free and silicon-free construction matters for installations in clean rooms, semiconductor fabs, or areas where outgassing can't contaminate optics or contacts.

Frequently asked questions

What is the breaking capacity of 5SN4350-7CN?

10 kA rated breaking capacity per EN 60898 at 400 V AC. That covers standard commercial and light industrial fault levels.

How do I get current pricing and availability for 5SN4350-7CN?

Submit an RFQ against this order code. Pricing and stock are confirmed at quote time through independent distribution channels.

MPN
5SN4350-7CN