Siemens 5SN6103-7CP — 1-Pole MCB (DIN Rail)

Siemens 5SN6103-7CP MCB, 1-Pole, C-Curve, 400 VAC, 6 kA

MPN5SN6103-7CP

Siemens SENTRON 5SN6103-7CP, 1-pole miniature circuit breaker, C-curve, 400 VAC, 6 kA (EN 60898), 18 mm wide.

Sourced new & surplus through independent channelsAuthenticity-screened · ESD-safe packingListing updated Jul 2026

Specifications

5SN6103-7CP — Identification
ParameterValue
Number of poles1
5SN6103-7CP — Mounting & Connection
ParameterValue
Width18 mm
Height90 mm
Depth76 mm
Installation depth70 mm
Modular width units1
Torque, min.-40 °C
Torque, max.75 °C

Product details

The 72 V DC maximum rating means it can also switch DC control circuits, but only up to that voltage. The 18 mm width (one modular unit) and 76 mm depth fit standard DIN-rail enclosures. The -40 °C to 75 °C operating range means it survives the nacelle: no up-tower swaps for cold-soak starts.

The closest peer is the 5SL6006-7, also a 1-module SENTRON MCB with the same 76 mm depth, 18 mm width, 70 mm installation depth, and -40 °C to 75 °C range. The 5SL6006-7 is a 1P+N design (switches neutral) rated 230 VAC single-phase, while the 5SN6103-7CP is a straight 1-pole breaker rated 400 VAC for multi-phase operation. If your panel was wired around the 5SL6006-7 and you need 400 V phase-to-phase capability, the 5SN6103-7CP drops into the same DIN footprint with no rewiring — same 18 mm slot, same terminal range up to 35 mm². The 5SL6006-7 carries a slightly higher 1.4 W power loss per pole; the 5SN6103-7CP runs at 1.3 W.

Snap-on DIN rail mounting, any position. Solid conductors up to 35 mm² fit the terminals; strip length for the cage clamp follows standard practice. The 10 000 mechanical operating cycles typical service life suits panel access for isolation, not daily switching duty.

Frequently asked questions

What is 5SN6103-7CP's listed depth (76 mm) on this component line?

The depth is 76 mm with an installation depth of 70 mm. The 6 mm difference accounts for the DIN-rail clip and terminal clearance behind the rail.

What is 5SN6103-7CP's listed width (18 mm) on this component line?

The width is 18 mm, which is one modular unit (1 MW). It occupies a single 18 mm slot on the DIN rail.

Will 5SN6103-7CP drop into a panel that was specified around 5SL6006-7 without rewiring?

Yes — both share the same 18 mm width, 76 mm depth, 70 mm installation depth, and accept conductors up to 35 mm². The 5SN6103-7CP is a straight 1-pole breaker rated for 400 VAC multi-phase, whereas the 5SL6006-7 is a 1P+N design rated 230 VAC. No DIN-rail or terminal change needed.

What compliance documentation does this brand provide for 5SN6103-7CP (RoHS, REACH, UL, IEC)?

The breaker is rated per EN 60898 (6 kA) and IEC 60947-2 (30 kA). The SENTRON series typically carries CE, UL, and CSA certifications; specific RoHS/REACH declarations are available from the manufacturer upon request through the RFQ process.

How do I get current pricing and availability for 5SN6103-7CP?

Submit an RFQ through this listing. The part is sourced to order through independent distribution; current pricing and stock levels are confirmed at quote time.