Skip to main content
Siemens 5SN6163-7CN — 1-Pole MCB (DIN Rail)

Siemens 5SN6163-7CN SENTRON MCB, 1P C 63A 6kA

MPN5SN6163-7CN

Siemens SENTRON 5SN6163-7CN, miniature circuit breaker, 1-pole, tripping characteristic C, 63 A rated current, 6 kA breaking capacity per EN 60898, 400 V AC, 50/60 Hz.

Sourced new & surplus through independent channelsAuthenticity-screened · ESD-safe packingListing updated Aug 2026

Specifications

5SN6163-7CN — Identification
ParameterValue
Product designationMiniature circuit breaker
Brand nameSENTRON
Number of poles1
Pole design1P
5SN6163-7CN — Electrical & Protection
ParameterValue
Tripping characteristic classC
Energy limitation class3
Overvoltage categoryIII
5SN6163-7CN — Mounting & Connection
ParameterValue
Mounting positionany
Width18 mm
Height90 mm
Depth76 mm
Installation depth70 mm
Modular width units1
Torque, min.-40 °C
Torque, max.75 °C
SealableYes
5SN6163-7CN — Environmental
ParameterValue
IP protection classIP20, with connected conductors
Pollution degree2
Halogen-freeYes
Silicone-freeYes

Product details

What it is and what it does

The Siemens SENTRON 5SN6163-7CN is a 1-pole miniature circuit breaker with a C-curve trip characteristic, rated 63 A at 400 V AC, 50/60 Hz. Its 6 kA breaking capacity per EN 60898 covers most residential and light commercial distribution boards. The C-curve means it trips between 5 and 10 times rated current — standard for general-purpose loads like lighting, socket circuits, and small appliances where inrush isn't extreme.

Panel fit and integration

Occupies a single 18 mm modular width unit (1 MW) on standard DIN rail. Depth of 76 mm and 70 mm installation depth mean it clears most shallow enclosures. Mounting position is any — no derating for horizontal or inverted orientation. IP20 with connected conductors is typical for enclosed distribution boards; touch protection is built in.

Wiring and accessories

Accepts solid conductors up to 25 mm² — generous for a 63 A breaker, allowing easy termination of larger feed cables. Power loss is 5 W per pole at rated current in hot state, which matters for thermal coordination inside a crowded enclosure. Sealable design supports lockout/tagout procedures. Supplementary devices (auxiliary contacts, shunt trips, alarm switches) can be added via the product extension feature.

Frequently asked questions

What is the breaking capacity of the 5SN6163-7CN?

6 kA according to EN 60898 at 400 V AC. This covers most residential and light commercial installations; for higher fault currents (e.g., 10 kA), consider the 5SL series.

What conductor sizes does the 5SN6163-7CN accept?

Solid conductors up to 25 mm². That's oversized for a 63 A breaker, making termination of larger feed cables straightforward.

Can I get pricing and availability for the 5SN6163-7CN?

Sourced and quoted to order against an RFQ through independent distribution. Current pricing and availability are confirmed at quote time.

MPN
5SN6163-7CN