Skip to main content
Siemens 5SN6201-7CP — 2-Pole MCB (DIN Rail)

Siemens 5SN6201-7CP 2-Pole MCB, 400V AC, 6kA/30kA

MPN5SN6201-7CP

Siemens SENTRON 5SN6201-7CP, 2-pole MCB, 400 V AC, 50 Hz, 6 kA per EN 60898 / 30 kA per IEC 60947-2, 72 V DC max, 2 MWU.

Sourced new & surplus through independent channelsAuthenticity-screened · ESD-safe packingListing updated Aug 2026

Specifications

5SN6201-7CP — Electrical
ParameterValue
Number of poles2
Supply voltage at AC rated value400 V
5SN6201-7CP — Mechanical
ParameterValue
Modular width units2
Width36 mm
Height90 mm
Depth76 mm
Installation depth70 mm
Min.-40 °C
Max.75 °C
5SN6201-7CP — Specifications
ParameterValue
According to EN 60898 rated value6 kA
With single-phase operation at AC rated value440 V

Product details

The Siemens 5SN6201-7CP is a 2-pole miniature circuit breaker from the SENTRON 5SN series, rated for 400 V AC at 50 Hz. Its interrupting capacity is 6 kA per EN 60898 for standard branch-circuit protection, and 30 kA per IEC 60947-2 for industrial panel coordination — the 30 kA figure is the one that governs SCCR headroom in a distribution board with upstream transformer capacity. On the DC side, it handles up to 72 V, which covers 48 V control loops and some 60 V battery banks, but not 110 V DC telecom plants.

No official successor has been issued. If a direct cross-reference is needed for a second-source gate, the SENTRON 5SY7206-7CC shares the same 2-pole, 400 V AC, 30 kA (IEC 60947-2) footprint and 2-MWU width — the difference is in the tripping characteristic curve and auxiliary accessory compatibility, not the basic fit.

Integration Notes

Accepts solid conductors up to 35 mm² at the terminals.

Frequently asked questions

What is the closest functional second-source for 5SN6201-7CP?

The SENTRON 5SY7206-7CC is the closest peer: same 2-pole, 400 V AC, 30 kA (IEC 60947-2) rating, same 2-MWU DIN-rail footprint. The tripping characteristic differs, so verify coordination before dropping it into an existing selectivity study.

Will 5SN6201-7CP drop into a panel specified around 5SY7206-7CC without rewiring?

Yes — both share the same 36 mm width, 76 mm depth, 70 mm installation depth, and DIN-rail mounting. Terminal capacity is identical. No rewiring needed for the physical swap, but confirm the tripping curve matches the circuit protection requirement.

What are the key interrupting ratings for 5SN6201-7CP?

6 kA per EN 60898 for standard branch-circuit protection, and 30 kA per IEC 60947-2 for industrial panel coordination. The 30 kA figure is the one that determines SCCR compliance in a distribution board.

Where can I buy 5SN6201-7CP and how is it quoted?

Sourced and quoted to order against an RFQ through independent distribution. Availability and current pricing are confirmed at quote time — no stock count or price is published here.

MPN
5SN6201-7CP