Skip to main content
Siemens 5SN6204-7CP — 2-Pole MCB (DIN Rail)

Siemens 5SN6204-7CP MCB, 2-pole, 400 V AC, 6 kA EN 60898

MPN5SN6204-7CP

Siemens SENTRON 5SN MCB, 2-pole, 400 V AC, 6 kA (EN 60898) / 30 kA (IEC 60947-2), 50 Hz, 2 MW units, 76 × 36 × 90 mm.

Sourced new & surplus through independent channelsAuthenticity-screened · ESD-safe packingListing updated Aug 2026

Specifications

5SN6204-7CP — Electrical
ParameterValue
Number of poles2
Supply voltage at AC rated value400 V
5SN6204-7CP — Mechanical
ParameterValue
Modular width units2
Width36 mm
Height90 mm
Depth76 mm
Installation depth70 mm
Min.-40 °C
Max.75 °C
5SN6204-7CP — Specifications
ParameterValue
According to EN 60898 rated value6 kA
With single-phase operation at AC rated value440 V

Product details

Siemens 5SN6204-7CP — 2-pole MCB for 400 V AC panels

The Siemens 5SN6204-7CP is a 2-pole miniature circuit breaker from the SENTRON 5SN series, rated for 400 V AC at 50 Hz with a breaking capacity of 6 kA per EN 60898 and 30 kA per IEC 60947-2. It occupies 2 modular width units (36 mm) on a DIN rail, with a depth of 76 mm and installation depth of 70 mm. The DC rating goes up to 72 V. This is the breaker you spec into a distribution board when you need the higher IEC 60947-2 fault-clearing margin for industrial panel coordination — the 30 kA rating means it can interrupt faults up to that level without cascading upstream, which is what makes it different from a residential-grade 6 kA-only unit.

Width is 36 mm (2 MW), depth 76 mm, height 90 mm. Accepts solid conductors up to 35 mm².

The dual breaking-capacity rating is the key spec: 6 kA per EN 60898 covers the residential and light commercial requirement, while 30 kA per IEC 60947-2 lets the breaker serve in industrial panels where fault currents are higher. The 2-pole configuration with 400 V AC multi-phase rating means it switches both phase conductors in a single-phase or two-phase circuit — common for 400 V line-to-line loads or sub-distribution. Mechanical life of 10,000 operating cycles is typical for this class; power loss of 1.3 W per pole at rated current matters for thermal budgeting in a densely populated enclosure.

Frequently asked questions

What is the breaking capacity of 5SN6204-7CP?

6 kA per EN 60898 and 30 kA per IEC 60947-2. The 30 kA rating is the one that matters for industrial panel coordination — it safely interrupts faults up to that level without cascading upstream.

Where can I buy 5SN6204-7CP?

Sourced and quoted to order against an RFQ through independent distribution. Availability and current pricing are confirmed at quote time.

Does 5SN6204-7CP work on DC circuits?

Yes, it is rated for DC operation up to 72 V maximum.

What conductor size does 5SN6204-7CP accept?

Solid conductors up to 35 mm².

MPN
5SN6204-7CP