Siemens 5SN6350-7CP — Miniature Circuit Breakers (MCB)

Siemens 5SN6350-7CP SENTRON MCB, 3-Pole, C-Curve, 10 kA IEC

MPN5SN6350-7CP

Siemens SENTRON 5SN6350-7CP, 3-pole miniature circuit breaker, C-curve, 400 V AC, 6 kA (EN 60898) / 10 kA (IEC 60947-2), 3 modular width units.

Source DocumentedChannel stated on listing & quote
Condition PhotosReal unit photos / video on request
WhatsApp AnswersFast human replies for machine-down parts
Worldwide DispatchDHL/FedEx — transit quoted per order
Independent China distributor & sourcing agent· Listing updated Sep 2026

Specifications

5SN6350-7CP — Mechanical
ParameterValue
Width54 mm
Height90 mm
Depth76 mm

Product details

Siemens SENTRON 5SN6350-7CP — 3-Pole C-Curve MCB

Rated for multi-phase operation at 440 V AC maximum, and single-phase operation also at 440 V AC — the same voltage ceiling regardless of how many phases are loaded, so it handles line-to-line faults in a 400 V three-phase system without derating. DC rating tops out at 72 V, which covers 48 V control circuits but not 125 V DC battery banks. This is relevant for thermal coordination inside a sealed enclosure — adjacent devices must be spaced or derated if the internal ambient exceeds 40 °C. Installation depth is 70 mm, and overall dimensions (76 mm depth, 54 mm width, 90 mm height) match the standard SENTRON 3-pole footprint.

The closest functional peer in the SENTRON family is the 5SL4363-7, which shares the same 3-pole C-curve, same dimensions (76 mm depth, 54 mm width, 90 mm height), and same 10 kA rating per IEC 60947-2. The 5SL4363-7 carries a higher power loss per pole (5 W vs 3.8 W) and a 10 kA EN 60898 rating versus the 6 kA on the 5SN6350-7CP. Both mount on the same DIN-rail footprint and accept conductors up to 35 mm² solid. For a panel originally specified around the 5SL4363-7, the 5SN6350-7CP drops in without rewiring — same pole count, same modular width, same installation depth.

Frequently asked questions

What are the key ratings of the 5SN6350-7CP?

It is a 3-pole C-curve MCB rated for 400 V AC supply voltage, with a breaking capacity of 6 kA per EN 60898 and 10 kA per IEC 60947-2. It occupies 3 modular width units (54 mm) on a DIN rail.

Will the 5SN6350-7CP fit in a panel designed for the 5SL4363-7?

Yes, the 5SN6350-7CP shares the same dimensions (76 mm depth, 54 mm width, 90 mm height), same installation depth (70 mm), and same 3-pole DIN-rail footprint as the 5SL4363-7. It drops in without rewiring.

What is the 5SN6350-7CP rated for in terms of conductor size and temperature?

It accepts solid conductors up to 35 mm² and operates over a temperature range of -40 °C to 75 °C.

Where can I buy the 5SN6350-7CP?

The 5SN6350-7CP is sourced and quoted to order against an RFQ through independent distribution. Availability and current pricing are confirmed at quote time.

MPN
5SN6350-7CP