Skip to main content
Siemens 5SN6350-8CP — 3-Pole MCB (DIN Rail)

Siemens 5SN6350-8CP SENTRON MCB, 3-Pole, C-Curve, 6 kA

MPN5SN6350-8CP

Siemens SENTRON 5SN series, miniature circuit breaker, 3-pole, C-trip characteristic, 400 V AC, 50 Hz, 6 kA (EN 60898) / 10 kA (IEC 60947-2), 3 modular width units.

StockContact for availability
MOQ1 pcs
Sourced new & surplus through independent channelsListing updated Jul 2026

Specifications

Identification

5SN6350-8CP — Identification
ParameterValue
Number of poles3

Protection

5SN6350-8CP — Protection
ParameterValue
Breaking capacity per EN 608986 kA
Breaking capacity per IEC 60947-210 kA

Electrical

5SN6350-8CP — Electrical
ParameterValue
Rated voltage (AC, multi-phase)440 V
Power loss per pole at rated current (AC, hot)3.7 W
Mechanical service life (operating cycles, typ.)10 000
Rated voltage (AC, single-phase)440 V

Mechanical

5SN6350-8CP — Mechanical
ParameterValue
Modular width units3
Width54 mm
Height90 mm
Depth76 mm
Installation depth70 mm
Terminal tightening torque, max.75 °C
Terminal tightening torque, min.-40 °C

Product details

Siemens 5SN6350-8CP — 3-pole C-curve MCB for 400 V AC distribution

The Siemens 5SN6350-8CP is a 3-pole miniature circuit breaker from the SENTRON 5SN family, rated 400 V AC at 50 Hz with a C-trip characteristic. It carries a 6 kA breaking capacity per EN 60898 and 10 kA per IEC 60947-2 — the IEC 60947-2 figure is the one that governs industrial panel SCCR calculations, so that 10 kA rating is the number to use when coordinating with upstream protection in a distribution board.

DIN-rail fit and panel integration

Occupies 3 modular width units (54 mm) on a standard DIN rail, with a depth of 76 mm and installation depth of 70 mm — the same footprint as the 5SL and 5SJ series, so it drops into an existing SENTRON panel without rewiring or re-spacing. Accepts solid conductors up to 35 mm², which covers most downstream feeder and branch circuits in a 400 V distribution board.

Breaking capacity and coordination

Two breaking-capacity ratings are listed: 6 kA per EN 60898 (the residential/commercial standard) and 10 kA per IEC 60947-2 (the industrial standard). For a panel feeding motor control centers or variable-frequency drives, the 10 kA IEC 60947-2 rating is the one that determines SCCR headroom and selectivity with upstream molded-case breakers. The C-curve (tripping between 5× and 10× rated current) handles moderate inrush from small motors and transformers without nuisance trips.

Lifecycle and sourcing

Current production. Quoted to order against RFQ through independent distribution.

Frequently asked questions

What is 5SN6350-8CP's listed depth?

76 mm overall depth, with an installation depth of 70 mm behind the DIN-rail mounting surface.

MPN
5SN6350-8CP