Skip to main content
Siemens 5SN6406-7CP — Miniature Circuit Breakers (MCB)

Siemens 5SN6406-7CP MCB, 4-pole, 400 V AC, 6 kA / 30 kA

MPN5SN6406-7CP

Siemens SENTRON 5SN6406-7CP miniature circuit breaker, 4-pole, 400 V AC, 50 Hz, 6 kA (EN 60898) / 30 kA (IEC 60947-2), 72 mm wide, 4 modular width units.

Source DocumentedChannel stated on listing & quote
Condition PhotosReal unit photos / video on request
WhatsApp AnswersFast human replies for machine-down parts
Worldwide DispatchDHL/FedEx — transit quoted per order
Independent China distributor & sourcing agent· Listing updated Sep 2026

Specifications

5SN6406-7CP — Mechanical
ParameterValue
Width72 mm
Height90 mm
Depth76 mm

Product details

Siemens 5SN6406-7CP — 4-pole MCB for 400 V AC distribution

The Siemens 5SN6406-7CP is a 4-pole miniature circuit breaker from the SENTRON 5SN series, rated for 400 V AC at 50 Hz and a 6 kA breaking capacity per EN 60898, with a higher 30 kA rating per IEC 60947-2 for industrial fault-current duty. The dual breaking-capacity rating means the 5SN6406-7CP is listed for both residential/infrastructure panels (6 kA per EN 60898) and industrial switchgear (30 kA per IEC 60947-2), giving the specifying engineer headroom for high-fault locations without changing the breaker footprint.

DC-side rating goes to 72 V maximum — useful for control-circuit tapping off the same bus, but the primary duty is AC distribution. Terminals accept solid conductors up to 35 mm², covering most feeder and branch-circuit wire sizes in a 400 V panel.

The 76 mm overall depth includes the front projection. Standard SENTRON accessory footprint — auxiliary switches, shunt trips, and under-voltage releases from the 5ST3 series clip onto the right side without increasing the width.

Frequently asked questions

What is the breaking capacity of 5SN6406-7CP?

6 kA per EN 60898 and 30 kA per IEC 60947-2, giving the breaker dual certification for both residential and industrial fault-current levels.

Will 5SN6406-7CP drop into a panel specified around 5SY5416-7 without rewiring?

Yes — the 5SN6406-7CP shares the same 72 mm width (4 MW), 70 mm installation depth, and DIN-rail mounting as the 5SY5416-7, so it fits the same enclosure footprint. The 5SY5416-7 carries a higher 10 kA EN 60898 rating and adds DC capability to 880 V, but the mechanical dimensions are identical.

Where can I buy 5SN6406-7CP?

Sourced and quoted to order against an RFQ through independent distribution. Availability and current pricing are confirmed at quote time.

MPN
5SN6406-7CP