Skip to main content
Siemens 5SN6440-6CN — 4-Pole MCB (DIN Rail)

Siemens 5SN6440-6CN SENTRON MCB, 40A 4P B-curve 6kA

MPN5SN6440-6CN

Siemens SENTRON 5SN6440-6CN, miniature circuit breaker, 4-pole, B characteristic, 40 A rated current, 6 kA breaking capacity at 400 V AC per EN 60898, 4 MW units wide.

Sourced new & surplus through independent channelsAuthenticity-screened · ESD-safe packingListing updated Aug 2026

Specifications

5SN6440-6CN — Identification
ParameterValue
Brand nameSENTRON
5SN6440-6CN — Ratings
ParameterValue
Number of poles4
Pole configuration4P
Rated voltage, AC (multi-phase)440 V
5SN6440-6CN — Protection
ParameterValue
Tripping characteristic (trip curve)B
Energy limitation class3
Overvoltage categoryIII
Pollution degree2
Degree of protection (IP)IP20, with connected conductors
5SN6440-6CN — Mechanical
ParameterValue
Width in modular units4
Width72 mm
Height90 mm
Depth76 mm
Installation depth70 mm
Mounting positionany
Tightening torque, max.75 °C
Tightening torque, min.-40 °C
SealableYes
5SN6440-6CN — Environmental
ParameterValue
Halogen-freeYes
Silicone-freeYes
Influence of ambient temperature (derating)Periodically +55°C, max. 95% humidity
5SN6440-6CN — Performance
ParameterValue
Power loss per pole, AC (hot state, at In)3.4 W

Product details

What it is and what it does

The Siemens 5SN6440-6CN is a 4-pole SENTRON miniature circuit breaker with a B tripping characteristic, rated 40 A at 400 V AC, 50/60 Hz. Its 6 kA breaking capacity per EN 60898 covers standard residential and commercial branch circuit protection. The B curve means it trips between 3 and 5 times rated current — suited for resistive and general-purpose loads where inrush is low, not for motor starting or transformer primaries.

Fit and footprint

At 72 mm wide (4 modular width units), it occupies four standard 18 mm DIN-rail slots. Depth is 76 mm, installation depth 70 mm. Mounting position is any, so it works in horizontal or vertical panel layouts. The IP20 rating (with connected conductors) is typical for enclosed distribution boards — not for wet or outdoor locations without a secondary enclosure.

What the ratings mean for your panel

The 6 kA rated short-circuit capacity per EN 60898 at 400 V AC means it safely interrupts fault currents up to that level. Overvoltage category III and pollution degree 2 suit it for fixed-installation distribution boards. Energy limitation class 3 means it lets through less let-through energy than class 1 or 2 breakers — better for protecting downstream equipment. The 3.4 W power loss per pole at rated current in hot state matters for thermal budgeting in a crowded enclosure.

Frequently asked questions

Where can I buy 5SN6440-6CN and how do I get a price?

The part is sourced and quoted to order against an RFQ through independent distribution. Submit a request for quote; availability and current pricing are confirmed at quote time.

Will 5SN6440-6CN drop into a panel that was specified around 5SL4363-7 without rewiring?

No. The 5SN6440-6CN is 72 mm wide (4 MW units) versus 54 mm (3 MW) for the 5SL4363-7. It also has 4 poles instead of 3 and a B curve instead of C. The panel would need mechanical modification and circuit reconfiguration.

What compliance documentation does Siemens provide for 5SN6440-6CN?

The product is halogen-free and silicon-free. Standard documentation includes the datasheet, declaration of conformity per EN 60898, and material compliance declarations (RoHS, REACH) available on request.

MPN
5SN6440-6CN