Skip to main content
Siemens 5SP3235-3 — 2-Pole MCB (DIN Rail)

Siemens SENTRON 5SP3235-3 MCB, 35A 2P E-Curve, 25kA

MPN5SP3235-3
Active

Siemens SENTRON 5SP3 series, miniature circuit breaker (MCB), 2-pole, 35 A rated current, E tripping characteristic, 25 kA breaking capacity at 400 V AC, 50 Hz, standard rail mount.

Sourced new & surplus through independent channelsAuthenticity-screened · ESD-safe packingListing updated Aug 2026

Specifications

5SP3235-3 — Identification
ParameterValue
Product designationMiniature circuit breaker
Brand nameSENTRON
Application environmentResidential buildings/infrastructure
5SP3235-3 — Electrical
ParameterValue
Number of poles2
5SP3235-3 — Protection
ParameterValue
Tripping characteristic classE
Overvoltage categoryIV
5SP3235-3 — Mechanical
ParameterValue
Height128 mm
Depth76.3 mm
Min.-40 °C
Max.70 °C
Protection degree (IP)IP40, with connected conductors
5SP3235-3 — Environmental
ParameterValue
Pollution degree3

Product details

The Siemens SENTRON 5SP3235-3 is a 2-pole miniature circuit breaker (MCB) with an E tripping characteristic, rated 35 A at 400 V AC, 50 Hz.

The 3 width units (about 52.5 mm) occupy the same footprint as a typical 2-pole MCB. Terminals accept 2.5 to 50 mm² solid or stranded copper — that's a wide lug range, so you can land a 50 mm² feeder without a reducer. Saddle terminals and box-terminal infeed are standard; the integrated locking slide accepts a padlock, wire seal, or cable tie for lockout/tagout.

Environmental and electrical ratings

Rated insulation voltage 690 V, overvoltage category IV, pollution degree 3 — this is a heavy-duty mains-side breaker, not a control-circuit accessory. Surge voltage resistance 6 kV. Ambient range -40 to 70 °C, which covers most indoor panel conditions including unheated utility rooms. Shock tested to 30 g, 11 ms half-sine, and vibration per IEC 60068-2-6 at 2 g, 5–150 Hz — it will hold up in industrial settings with moderate vibration.

The 5SP3 series is a standard Siemens SENTRON line, widely used across European and export panels.

Frequently asked questions

What is the breaking capacity of the 5SP3235-3?

25 kA per EN 60898 at 400 V AC. That's the rated short-circuit capacity — it will safely interrupt a fault up to 25 kA without external fusing.

What is the E tripping characteristic used for?

The E curve (between B and K in magnetic trip threshold) is designed for main or distribution circuit breakers where you need a higher magnetic trip than a standard B or C curve to avoid nuisance tripping from transformer inrush or motor starting loads, but not as high as a K curve. Typical in residential and light commercial mains.

Where can I buy the 5SP3235-3?

This part is sourced and quoted to order against an RFQ through independent distribution. Availability and current pricing are confirmed at quote time — submit an RFQ for a firm offer.

MPN