Siemens 5SP3716-2KK01 — 1-Pole MCB (DIN Rail)

Siemens 5SP3716-2KK01 SENTRON MCB, 1P 16A E-Curve, 25kA

MPN5SP3716-2KK01

Siemens SENTRON 5SP3 series, miniature circuit breaker, 1-pole, 16 A, E characteristic, 25 kA breaking capacity, busbar mount.

Sourced new & surplus through independent channelsAuthenticity-screened · ESD-safe packingListing updated Aug 2026

Specifications

5SP3716-2KK01 — Identification
ParameterValue
Product designationMiniature circuit breaker
Brand nameSENTRON
Number of poles1
Application suitabilityResidential buildings/infrastructure
5SP3716-2KK01 — Electrical & Protection
ParameterValue
Tripping characteristic classE
Rated value (EN 60898)25 kA
Overvoltage categoryIV
5SP3716-2KK01 — Mounting & Connection
ParameterValue
Height151.3 mm
Depth89.5 mm
Torque, min.110 V
Torque, max.440 V
SealableYes
5SP3716-2KK01 — Environmental
ParameterValue
IP protection classIP40, with connected conductors

Product details

The Siemens 5SP3716-2KK01 is a 1-pole SENTRON miniature circuit breaker rated 16 A at 230 V AC, 50 Hz, with an E tripping characteristic and a 25 kA breaking capacity per EN 60898. It mounts on a 40-mm busbar system per DIN 43870 Part 2, which is the standard meter-panel busbar pitch in European residential and infrastructure installations. The 1.5 width units (roughly 27 mm) keep the footprint tight in a multi-pole distribution board. Infeed is via box terminal at the top; outgoing is through a spring-loaded terminal, so no screw torque is needed on the load side — just strip and push.

Where it goes and what it protects

This breaker is designed for residential buildings and infrastructure — think apartment distribution boards, light commercial sub-panels, or meter cabinets. The E characteristic is less common than B or C in general-purpose circuits, but it's specified where the load has a known high inrush that would trip a C curve on energisation: small transformers, power supplies, or capacitor banks. The enclosure depth is 76.3 mm, and the overall depth including terminals is 89.5 mm — that's the dimension to check against a shallow meter-panel lid.

Frequently asked questions

What is the breaking capacity of 5SP3716-2KK01?

The rated breaking capacity per EN 60898 is 25 kA at 230 V AC. That's the maximum fault current the breaker can safely interrupt under standard test conditions.

What does the E tripping characteristic mean?

The E curve trips magnetically between 10× and 20× the rated current (In). For this 16 A breaker, that means instantaneous magnetic trip occurs between 160 A and 320 A. It's wider than a C curve (5–10× In), so it's chosen for loads with higher inrush that would nuisance-trip a C-curve breaker.

Where can I buy 5SP3716-2KK01 and get current pricing?

This part is sourced and quoted to order against an RFQ through independent distribution. Availability and current pricing are confirmed at quote time — submit an RFQ for a firm price and lead time.

What wire sizes does 5SP3716-2KK01 accept?

The terminals accept solid and stranded conductors from 2.5 mm² up to 50 mm². That covers standard building wire sizes from lighting circuits up to feeder conductors.

Will 5SP3716-2KK01 fit in a meter panel with a 40-mm busbar system?

Yes, it's designed for mounting on a 40-mm busbar system in compliance with DIN 43870 Part 2, which is the standard for European meter panels. The overall depth is 89.5 mm, so check the panel lid clearance.

MPN
5SP3716-2KK01