Skip to main content
Siemens 5SP3735-2KK01 — 1-Pole MCB (DIN Rail)

Siemens 5SP3735-2KK01 SENTRON MCB, 1P 35A, 25kA, Char E

MPN5SP3735-2KK01

Siemens SENTRON 5SP3 series miniature circuit breaker, 1-pole, 35 A rated current, 25 kA breaking capacity, tripping characteristic E, for 40-mm busbar mounting.

Sourced new & surplus through independent channelsAuthenticity-screened · ESD-safe packingListing updated Aug 2026

Specifications

5SP3735-2KK01 — Identification
ParameterValue
Product designationMiniature circuit breaker
Brand nameSENTRON
Number of poles1
Application suitabilityResidential buildings/infrastructure
5SP3735-2KK01 — Electrical & Protection
ParameterValue
Tripping characteristic classE
Rated value (EN 60898)25 kA
Overvoltage categoryIV
5SP3735-2KK01 — Mounting & Connection
ParameterValue
Height151.3 mm
Depth89.5 mm
Torque, min.110 V
Torque, max.440 V
SealableYes
5SP3735-2KK01 — Environmental
ParameterValue
IP protection classIP40, with connected conductors

Product details

The Siemens 5SP3735-2KK01 is a 1-pole SENTRON miniature circuit breaker (MCB) from the 5SP3 series, rated for 35 A at 230 V AC, 50 Hz, with a 25 kA breaking capacity per EN 60898. The E tripping characteristic is designed for selective coordination in residential and infrastructure distribution boards — it holds through motor inrush and transformer magnetizing currents without nuisance tripping, then clears hard faults fast.

Mounts directly onto a 40-mm busbar system per DIN 43870 Part 2 — the standard meter-panel grid found across European residential and light-commercial infrastructure. Occupies 1.5 width units, so it fits a compact footprint. Infeed is via the box terminal at the bottom; outgoing feeder uses a spring-loaded terminal. The enclosure depth is 76.3 mm; overall depth including terminals is 89.5 mm — check your cabinet clearance if using deep gland plates.

Environmental and mechanical ruggedness

Shock-rated to 30 g (11 ms duration, 3 impacts) and vibration-tested per IEC 60068-2-6 at 2 g, 20 cycles from 5 to 150 Hz. Overvoltage category IV, surge voltage resistance 6 kV — suitable for utility-side installation where lightning-induced surges are a concern.

Frequently asked questions

Where can I buy 5SP3735-2KK01 and how do I get a price?

This part is sourced through independent distribution and quoted to order against an RFQ. Submit a request for quote; availability and current pricing are confirmed at that time.

What is 5SP3735-2KK01's listed depth?

Overall depth is 89.5 mm; the enclosure depth alone is 76.3 mm. Verify cabinet clearance if using deep gland plates or tight wire bends.

What conductor sizes does 5SP3735-2KK01 accept?

Accepts solid or stranded conductors from 2.5 mm² up to 50 mm². The spring-loaded outgoing terminal handles the full range.

What compliance documentation does this brand provide for 5SP3735-2KK01?

The product carries a 25 kA breaking capacity rating per EN 60898 and overvoltage category IV per IEC standards. Typical SENTRON documentation includes CE declaration, RoHS/REACH compliance statements, and IEC test reports — available on request with your RFQ.

MPN
5SP3735-2KK01