Siemens 5SP3750-2XX02 — 1-Pole MCB (DIN Rail)

Siemens 5SP3750-2XX02 SENTRON MCB, 1P, 50 A, E-Curve, 25 kA

MPN5SP3750-2XX02

Siemens SENTRON 5SP3 series, main miniature circuit breaker (SHU), 1-pole, 50 A, E tripping characteristic, 25 kA breaking capacity, 230/400 V AC, busbar mount.

Sourced new & surplus through independent channelsAuthenticity-screened · ESD-safe packingListing updated Jul 2026

Specifications

5SP3750-2XX02 — Identification
ParameterValue
Product designationMiniature circuit breaker
Brand nameSENTRON
Number of poles1
Application suitabilityResidential buildings/infrastructure
5SP3750-2XX02 — Electrical & Protection
ParameterValue
Tripping characteristic classE
Rated value (EN 60898)25 kA
Overvoltage categoryIV
5SP3750-2XX02 — Mounting & Connection
ParameterValue
Torque, min.-40 °C
Torque, max.70 °C
SealableYes
5SP3750-2XX02 — Environmental
ParameterValue
IP protection classIP40, with connected conductors

Product details

The Siemens 5SP3750-2XX02 is a SENTRON main miniature circuit breaker (MCB) — specifically the 5SP3 design, a 1-pole unit rated 50 A with an E tripping characteristic. It's built as the main disconnect in a meter panel or distribution board, not a branch breaker. The E-curve means it's designed for longer time-delay before tripping on overload, which suits it for feeding sub-distribution or loads with moderate inrush where you don't want nuisance trips from a brief surge. That's the highest category for distribution boards, meaning it's tested for direct utility-side surges, not just internal switching transients.

Mounts on a 40-mm busbar system per DIN 43870 Part 2. Not for outdoor or washdown use. Sealable, so the utility can lock the cover after installation. The switch position indicator shows OFF = green, ON = red, which is the standard European color convention for main disconnects.

Environmental and mechanical specs

Shock resistance is 30 g for at least 3 impacts at 11 ms duration, and vibration resistance is 2 g over 20 frequency cycles from 5 to 150 Hz per IEC 60068-2-6. Mechanical service life is 20 000 switching cycles typical — that's about double what a standard branch MCB like the 5SL series offers (10 000 cycles), which makes sense for a main breaker that might see occasional manual operation for isolation.

Frequently asked questions

What is 5SP3750-2XX02's temperature range?

Rated ambient temperature range is -40 °C to 70 °C.

Will 5SP3750-2XX02 drop into a panel specified around 5SL6563-7BB without rewiring?

No — the 5SP3750-2XX02 mounts on a 40-mm busbar system per DIN 43870 Part 2, while the 5SL6563-7BB is a DIN-rail snap-on device. They use different mounting methods and footprints, so a direct swap without panel rework is not possible. The 5SP3 is a main breaker for meter panels; the 5SL6 is a branch breaker for distribution boards.

MPN
5SP3750-2XX02