Skip to main content
Siemens 5SP3763 — 1-Pole MCB (DIN Rail)

Siemens 5SP3763 SENTRON MCB, 1P 63A Class E, 25kA

MPN5SP3763

Siemens SENTRON 5SP3 series, main miniature circuit breaker (SHU), selective, 1-pole, 63 A, Class E, 25 kA per EN 60898, standard rail mount.

Sourced new & surplus through independent channelsAuthenticity-screened · ESD-safe packingListing updated Jul 2026

Specifications

5SP3763 — Identification
ParameterValue
Product designationMiniature circuit breaker
Brand nameSENTRON
Number of poles1
Application suitabilityResidential buildings/infrastructure
5SP3763 — Electrical & Protection
ParameterValue
Tripping characteristic classE
Rated value (EN 60898)25 kA
Overvoltage categoryIV
5SP3763 — Mounting & Connection
ParameterValue
Torque, min.-40 °C
Torque, max.70 °C
SealableYes
5SP3763 — Environmental
ParameterValue
IP protection classIP20, with connected conductors
Pollution degree3

Product details

Selective main MCB for high-fault installations

The Siemens SENTRON 5SP3763 is a 1-pole main miniature circuit breaker rated 63 A at 230 V AC, 50 Hz, with a 25 kA breaking capacity per EN 60898 — that's the short-circuit rating that decides whether this holds or blows upstream in a residential or infrastructure panel. The Class E tripping characteristic means it's selective (time-delayed) relative to downstream standard MCBs, so a fault on a branch circuit trips the branch breaker, not this main. That selectivity is the whole point: you don't lose the entire panel when a single lighting circuit shorts. That's the spec set for a service entrance or sub-distribution board, not a branch circuit.

Depth is 92 mm, which is deeper than the 5SL series (76 mm) — so if you're swapping from a 5SL6563-7BB, check the enclosure depth. The extra depth houses the selective trip mechanism. Sealable with a lead seal, and the supply cord can be connected in any position. Vibration resistance is 2 g per IEC 60068-2-6, shock resistance 30 g for 11 ms — tough enough for transport and seismic zones.

Environmental range and compliance

Operating temperature spans -40 °C to 70 °C. Mechanical service life is 20,000 switching cycles typical.

Frequently asked questions

When sourcing 5SP3763, what's the closest functional second-source — 5SL6563-7BB?

The 5SL6563-7BB is a 2-pole C-curve branch breaker, not a functional second-source for the 1-pole Class E selective main breaker 5SP3763. The 5SP3763 is deeper (92 mm vs 76 mm) and has a different trip characteristic — they serve different roles in the panel.

What is 5SP3763's listed maximum (70 °C) on this component line?

The maximum operating temperature is 70 °C.

What is 5SP3763's listed minimum (-40 °C) on this component line?

The minimum operating temperature is -40 °C.

Will 5SP3763 drop into a panel that was specified around 5SL6563-7BB without rewiring?

No — the 5SP3763 is 92 mm deep versus 76 mm for the 5SL6563-7BB, so check enclosure depth. Also, the 5SP3763 is 1-pole while the 5SL6563-7BB is 2-pole (1P+N), so wiring and neutral handling differ. They are not drop-in interchangeable.

MPN