Skip to main content
Siemens 5SP3763-2KK01 — 1-Pole MCB (DIN Rail)

Siemens 5SP3763-2KK01 SENTRON MCB, 1-pole, 63 A, E-curve, 25

MPN5SP3763-2KK01

Siemens SENTRON 5SP3 series, main miniature circuit breaker (SHU), 1-pole, 63 A, E tripping characteristic, 25 kA breaking capacity, 230/400 V AC, 50 Hz, busbar mount.

Sourced new & surplus through independent channelsAuthenticity-screened · ESD-safe packingListing updated Aug 2026

Specifications

5SP3763-2KK01 — Identification
ParameterValue
Product designationMiniature circuit breaker
Brand nameSENTRON
Number of poles1
Application suitabilityResidential buildings/infrastructure
5SP3763-2KK01 — Electrical & Protection
ParameterValue
Tripping characteristic classE
Rated value (EN 60898)25 kA
Overvoltage categoryIV
5SP3763-2KK01 — Mounting & Connection
ParameterValue
Height151.3 mm
Depth89.5 mm
Torque, min.-40 °C
Torque, max.70 °C
SealableYes
5SP3763-2KK01 — Environmental
ParameterValue
IP protection classIP40, with connected conductors

Product details

The Siemens 5SP3763-2KK01 is a SENTRON 5SP3 main miniature circuit breaker (SHU) — a 1-pole, 63 A unit with an E tripping characteristic, rated 25 kA breaking capacity per EN 60898 at 230/400 V AC, 50 Hz. It's designed for residential and infrastructure meter panels, mounting on a 40-mm busbar system per DIN 43870 Part 2. The E curve means it's tailored for feeder protection where moderate inrush tolerance is needed — think main incomers or distribution subfeeds in building installations.

At 63 A, this breaker handles a substantial residential or light commercial main feed — enough for a multi-unit panel or a large single-family service. Overvoltage category IV (6 kV surge rating) confirms it's rated for the utility-side interface, not just downstream branch circuits. Insulation voltage is 690 V, giving headroom for 400 V line-to-line applications if needed. Physical fit: 89.5 mm deep, 151.3 mm high, occupying 1.5 width units on the busbar. The depth includes the enclosure at 76.3 mm plus the spring-loaded outgoing terminal. Sealable and lockable (locking slide with wire seal, cable ties, Antilux) for utility or authority sealing.

Integration notes

Mounts on a 40-mm busbar system per DIN 43870 Part 2 — standard for European meter panels. Infeed is via box terminal at the bottom (stipulated by installation in the lower section of the meter panel). Outgoing feeder uses a spring-loaded terminal, no screw torque to manage. Switch position indicator shows OFF = green, ON = red. Shock-rated to 30 g (3 impacts, 11 ms duration) and vibration-rated to 2 g per IEC 60068-2-6 — robust for transport and utility environment.

Frequently asked questions

What is the 5SP3763-2KK01 used for?

It's a main miniature circuit breaker (SHU) for residential and infrastructure meter panels, protecting a 63 A, 230/400 V AC feeder with an E tripping curve and 25 kA breaking capacity.

What are the key dimensions of the 5SP3763-2KK01?

Depth is 89.5 mm (enclosure depth 76.3 mm), height is 151.3 mm, and it occupies 1.5 width units on the busbar.

Where can I buy the 5SP3763-2KK01?

This part is sourced and quoted to order against an RFQ through independent distribution. Availability and current pricing are confirmed at quote time — submit an RFQ for a firm position.

Will the 5SP3763-2KK01 drop into a panel designed for the 5SL6563-7BB?

No — the 5SL6563-7BB is a 2-pole, 63 A, C-curve MCB with 6 kA breaking capacity, IP20, and a different footprint (76 mm deep, 90 mm high, 36 mm wide, 2 width units). The 5SP3763-2KK01 is a 1-pole, E-curve, 25 kA, IP40, busbar-mount main breaker with different dimensions and mounting. They are not drop-in replacements.

MPN
5SP3763-2KK01