Siemens 5SP4150-8 — 1-Pole MCB (DIN Rail)

Siemens SENTRON 5SP4150-8 MCB, 1P D 50A 10kA

MPN5SP4150-8

Siemens SENTRON 5SP4150-8 miniature circuit breaker, 1-pole, D tripping characteristic, 50 A rated current, 10 kA (EN 60898) / 20 kA (IEC 60947-2) breaking capacity at 400 V AC, tunnel terminals top and bottom.

Sourced new & surplus through independent channelsAuthenticity-screened · ESD-safe packingListing updated Jul 2026

Specifications

5SP4150-8 — Identification
ParameterValue
Product designationMiniature circuit breaker
Brand nameSENTRON
Number of poles1
5SP4150-8 — Electrical & Protection
ParameterValue
Tripping characteristic classD
Rated value (EN 60898)10 kA
5SP4150-8 — Mounting & Connection
ParameterValue
Installation depth70 mm
5SP4150-8 — Other specifications
ParameterValue
Tunnel terminals topYes
Design of the product5SP Miniature circuit breakers
Number of poles (Note)1P
Tunnel terminals bottomYes
Circuit-breaker (Design)5SP4
Current (at AC)50 A
Acc. to IEC 60947-2 / rated value20 kA
Supply voltage (at AC)400 V

Product details

It carries a 10 kA breaking capacity per EN 60898 for residential/commercial branch circuits and a 20 kA rating per IEC 60947-2 for industrial panel duty, both at 400 V AC.

Panel integration

The 5SP4150-8 mounts on standard DIN rail and occupies a single modular width unit. Installation depth is 70 mm, which matches the SENTRON 5SP and 5SY series — it drops into existing distribution boards without clearance issues.

Selectivity and coordination

For a site electrical engineer planning selective coordination, the 20 kA breaking capacity per IEC 60947-2 gives headroom above the 10 kA EN 60898 rating — the higher figure applies when the MCB is used in an industrial context where prospective fault current may exceed 10 kA. The D-curve's 10–20× In magnetic trip band means upstream devices need a delayed characteristic (e.g., SENTRON 5SP series with B or C curves, or a larger-frame MCCB) to maintain selectivity on high-impedance faults. The 50 A rating pairs naturally with motor branch circuits up to about 15 kW at 400 V three-phase, depending on starting current profile.

Frequently asked questions

What is the breaking capacity of the 5SP4150-8?

The 5SP4150-8 is rated 10 kA per EN 60898 and 20 kA per IEC 60947-2, both at 400 V AC. The higher figure applies when the MCB is used in industrial installations under IEC 60947-2.

How does the 5SP4150-8 compare to the 5SY7140-8CC?

The 5SY7140-8CC is a 40 A D-curve 1-pole MCB with 15 kA per IEC 60947-2, versus the 5SP4150-8 at 50 A and 20 kA. Both are SENTRON 1-pole units with 70 mm depth and tunnel terminals, but the 5SP4 series carries a higher interrupting rating and current — it is the heavier-duty choice for industrial motor branches. The 5SY7140-8CC also offers UL 1077 recognition at 5 kA, which the 5SP4150-8 does not list. Panel fit is identical (same DIN footprint and depth), so swapping between them requires no rewiring or enclosure modification.

Where can I buy the 5SP4150-8 and get current pricing?

The 5SP4150-8 is sourced to order against an RFQ through our independent distribution network. Availability and current pricing are confirmed at quote time — submit an RFQ for a firm commercial offer.