Siemens 5SP4250-8 — 2-Pole MCB (DIN Rail)

SENTRON 5SP4250-8 Miniature Circuit Breaker, 2P D 50A 400V

MPN5SP4250-8

SENTRON 5SP4 series miniature circuit breaker, 2-pole, D tripping characteristic, 50 A rated current, 400 V AC, 10 kA breaking capacity per EN 60898.

Sourced new & surplus through independent channelsAuthenticity-screened · ESD-safe packingListing updated Jul 2026

Specifications

5SP4250-8 — Identification
ParameterValue
Product designationMiniature circuit breaker
Brand nameSENTRON
5SP4250-8 — Electrical
ParameterValue
Number of poles2
5SP4250-8 — Protection
ParameterValue
Tripping characteristic classD
5SP4250-8 — Mechanical
ParameterValue
Installation depth70 mm
5SP4250-8 — Other specifications
ParameterValue
Tunnel terminals topYes
Design of the product5SP Miniature circuit breakers
Number of poles (Note)2P
Tunnel terminals bottomYes
Circuit-breaker (Design)5SP4
Current (at AC)50 A
Acc. to EN 60898 / rated value10 kA
Acc. to IEC 60947-2 / rated value20 kA
Supply voltage (at AC)400 V

Product details

The SENTRON 5SP4250-8 is a 2-pole miniature circuit breaker from the 5SP4 design family, rated 50 A at 400 V AC with a D tripping characteristic.

Where it lands in a panel

Installation depth is 70 mm — fits standard DIN-rail enclosures without bottoming out against the gland plate. Two-pole format (2P) switches both phase conductors, so it suits single-phase or split-phase subfeeds where you need full isolation.

Frequently asked questions

Where can I buy 5SP4250-8 and get a price?

The part is sourced to order against an RFQ through independent distribution channels. Submit an RFQ for current availability and pricing — confirmed at quote time, not from a static listing.

What is the closest functional second-source — 5SP4292-7?

The 5SP4292-7 is the same 2-pole 5SP4 family and same 70 mm depth, but it carries a C-curve instead of D-curve and is rated 440 V instead of 400 V. The D-curve on the 5SP4250-8 is the deciding factor for motor/transformer loads — a C-curve swap may nuisance-trip on high inrush. Footprint and tunnel terminals are identical, so a panel wired for the 5SP4292-7 accepts the 5SP4250-8 without rewiring, but the trip curve mismatch matters for the load type.

What compliance documentation does SENTRON provide for 5SP4250-8?

The part carries EN 60898 and IEC 60947-2 ratings, which implies CE marking for the European market. RoHS and REACH compliance is standard for current SENTRON production. For specific declarations or UL listing, verify against the nameplate or request the manufacturer's declaration with your RFQ.

MPN