Siemens 5SP4350-6 — 2-Pole MCB (DIN Rail)

SENTRON 5SP4350-6 Miniature Circuit Breaker, 3-Pole, B, 50 A

MPN5SP4350-6

SENTRON, 5SP Miniature circuit breakers, Miniature circuit breaker, 5SP4350-6, 3-pole, B-curve, 50 A, 400 V AC, 10 kA (EN 60898), 20 kA (IEC 60947-2), tunnel terminals top and bottom, installation depth 70 mm.

Sourced new & surplus through independent channelsAuthenticity-screened · ESD-safe packingListing updated Jul 2026

Specifications

5SP4350-6 — Identification
ParameterValue
Product designationMiniature circuit breaker
Brand nameSENTRON
5SP4350-6 — Electrical
ParameterValue
Number of poles3
5SP4350-6 — Protection
ParameterValue
Tripping characteristic classB
5SP4350-6 — Mechanical
ParameterValue
Installation depth70 mm
5SP4350-6 — Other specifications
ParameterValue
Tunnel terminals topYes
Design of the product5SP Miniature circuit breakers
Number of poles (Note)2P
Tunnel terminals bottomYes
Circuit-breaker (Design)5SP4
Current (at AC)50 A
Acc. to EN 60898 / rated value10 kA
Acc. to IEC 60947-2 / rated value20 kA
Supply voltage (at AC)400 V

Product details

What the ratings mean for your panel

The SENTRON 5SP4350-6 is a 3-pole miniature circuit breaker from the 5SP4 series, rated 50 A at 400 V AC with a B tripping characteristic. The B-curve means it trips at 3 to 5 times rated current — suited for resistive and general-purpose loads where inrush is low, like lighting or heating circuits, not motor starts. The 10 kA breaking capacity per EN 60898 covers most residential and light commercial panel faults; the higher 20 kA rating per IEC 60947-2 gives headroom for industrial distribution boards where fault currents are stiffer. Tunnel terminals on both top and bottom accept solid or stranded conductors, and the 70 mm installation depth fits standard DIN-rail enclosures without crowding the wiring channel.

Panel integration and wiring

Mounts on a standard DIN rail. The 70 mm installation depth leaves clearance for wiring ducts and adjacent breakers. Tunnel terminals accept conductors without needing ferrules — strip, insert, tighten. No special tools beyond a screwdriver.

Frequently asked questions

Will 5SP4350-6 drop into a panel specified around 5SP4380-7?

Both share the same 3-pole, 70 mm depth, and tunnel-terminal footprint, so mechanical fit is the same. The 5SP4380-7 is a C-curve breaker; the 5SP4350-6 is B-curve. If the panel design calls for C-curve (higher inrush tolerance), the B-curve may trip on motor or transformer loads. Check the load type before substituting.