Siemens 5SP4480-6 SENTRON MCB, 4P B-curve 80 A 10 kA

MPN5SP4480-6
Active

Siemens SENTRON 5SP4480-6, 4-pole B-curve miniature circuit breaker, 80 A rated current, 10 kA breaking capacity at 400 V AC, 6 MW width, DIN-rail mount.

Sourced new & surplus through independent channelsAuthenticity-screened · ESD-safe packingListing updated Aug 2026

Specifications

5SP4480-6 — Identification
ParameterValue
Brand nameSENTRON
5SP4480-6 — Ratings
ParameterValue
Number of poles4
Pole configuration4P
Rated voltage, AC (multi-phase)440 V
5SP4480-6 — Protection
ParameterValue
Tripping characteristic (trip curve)B
Overvoltage category3
Pollution degree3
Degree of protection (IP)IP20 with connected conductors, IP40 in the area of the handle with distribution cover
5SP4480-6 — Mechanical
ParameterValue
Width in modular units6
Width108 mm
Height90 mm
Depth76 mm
Installation depth70 mm
Fastening / mounting methodDIN rail and screw fixing
Mounting positionany
Tightening torque, max.75 °C
Tightening torque, min.-40 °C
SealableYes
5SP4480-6 — Environmental
ParameterValue
Halogen-freeYes
Silicone-freeYes
Influence of ambient temperature (derating)Max. 95% rel. humidity
5SP4480-6 — Performance
ParameterValue
Power loss per pole, AC (hot state, at In)7 W

Product details

The Siemens SENTRON 5SP4480-6 is a 4-pole miniature circuit breaker with a B tripping characteristic, rated at 80 A and 10 kA breaking capacity according to EN 60898 at 400 V AC. Rated for 50/60 Hz supply and 400/440 V AC, it handles the standard European three-phase panel voltage.

Snaps onto DIN rail or screws directly to the panel backplate — both fastening methods are supported. Mounts in any position, which simplifies layout in crowded enclosures. The IP20 rating applies with connected conductors; IP40 at the handle area when a distribution cover is fitted — fine for enclosed panels, not for open washdown areas.

Frequently asked questions

How do I get current pricing and availability for 5SP4480-6?

Submit an RFQ through this listing. Pricing and stock are confirmed at quote time; we source through independent distribution and quote to order.

What compliance documentation does this brand provide for 5SP4480-6 (RoHS, REACH, UL, IEC)?

The breaker is designed to EN 60898 (the 10 kA rating is per that standard), carries an overvoltage category 3 and pollution degree 3 rating, and is halogen-free and silicon-free. RoHS/REACH declarations are standard for Siemens SENTRON products; request them with the RFQ.

Will 5SP4480-6 drop into a panel that was specified around 5SL4363-7 without rewiring?

Both are 4-pole B-curve MCBs on DIN rail, but the 5SP4480-6 is rated 80 A with 10 kA breaking capacity, while the 5SL4363-7 is a different current rating and breaking capacity — check the panel's coordination study before swapping. The physical footprint (6 MW, 108 mm wide) is the same, so it fits the same DIN-rail slot.