Skip to main content
Siemens 5SP9313-7KC47 — 3-Pole MCB (DIN Rail)

Siemens 5SP9313-7KC47 SENTRON MCB, 3P C13A, 50 kA IEC 60947-

MPN5SP9313-7KC47

Siemens SENTRON 5SP9 series, 5SP9313-7KC47 miniature circuit breaker, 3-pole, C-curve, 13 A, 50 kA breaking capacity per IEC 60947-2 at 400 V AC, 4.5 width units.

Sourced new & surplus through independent channelsAuthenticity-screened · ESD-safe packingListing updated Jul 2026

Specifications

5SP9313-7KC47 — Identification
ParameterValue
Design / model code5SP9
Brand nameSENTRON
Number of poles3
5SP9313-7KC47 — Protection
ParameterValue
Tripping characteristic (curve)C
Breaking capacity per IEC 60947-250 kA
Overvoltage category3
IP protection classIP20, with connected conductors
5SP9313-7KC47 — Electrical
ParameterValue
Rated current (AC)440 V
5SP9313-7KC47 — Mechanical
ParameterValue
Mounting positionany
Installation depth92 mm
SealableYes
5SP9313-7KC47 — Environmental
ParameterValue
Halogen-freeYes
Silicone-freeYes
Influence of surrounding temperaturePeriodically +55°C, max. 95% humidity

Product details

The Siemens 5SP9313-7KC47 is a SENTRON 5SP9 miniature circuit breaker — 3-pole, C-curve, rated 13 A at 400 V AC.

At 4.5 width units (about 81 mm), it occupies three 18 mm pole positions plus one half-module — plan the DIN rail fill accordingly. Tunnel terminals top and bottom accept solid or stranded conductors from 0.75 mm² up to 50 mm² (AWG 14–2), with a tightening torque of 2.5–3.5 N·m (22–31 lbf·in). That cross-section range covers everything from control-circuit tails to main feeder tails in a sub-distribution board.

Protection class IP20 with connected conductors; overvoltage category III. Shock resistance tested to 150 m/s² at 11 ms half-sine per IEC 60068-2-27; vibration resistance to 50 m/s² at 25–150 Hz and 60 m/s² at 35 Hz per IEC 60068-2-6. Mechanical service life is 20,000 switching cycles typical.

Frequently asked questions

What conductor sizes does 5SP9313-7KC47 accept?

Solid and stranded conductors from 0.75 mm² up to 50 mm² (AWG 14–2). Tunnel terminals are provided top and bottom.

Where can I buy the 5SP9313-7KC47?

This part is sourced and quoted to order against an RFQ through independent distribution channels. Availability and current pricing are confirmed at quote time.

What is the difference between 5SP9313-7KC47 and the 5SL series?

The 5SL series (e.g., 5SL4363-7) is an older SENTRON platform. The 5SP9 series uses the same DIN-rail footprint and tunnel-terminal wiring, but the 5SP9313-7KC47 carries a 50 kA breaking capacity per IEC 60947-2, which is higher than typical 5SL ratings. Verify the existing panel's SCCR and available fault current before substituting — the 5SP9 may be specified where higher interrupting capacity is required.

MPN
5SP9313-7KC47