Skip to main content
Siemens 5SP9332-7KC47 — 3-Pole MCB (DIN Rail)

SENTRON 5SP9332-7KC47 Miniature Circuit Breaker, 3P C 32A 50

MPN5SP9332-7KC47

SENTRON 5SP9332-7KC47 miniature circuit breaker, 3-pole, C tripping characteristic, 32 A rated current, 50 kA breaking capacity per IEC 60947-2, 400 V AC, 50 Hz.

$560.84Ref. price · indicative, final on quote
Sourced new & surplus through independent channelsAuthenticity-screened · ESD-safe packingListing updated Jul 2026

Specifications

5SP9332-7KC47 — Identification
ParameterValue
Design / model code5SP9
Brand nameSENTRON
Number of poles3
5SP9332-7KC47 — Protection
ParameterValue
Tripping characteristic (curve)C
Breaking capacity per IEC 60947-250 kA
Overvoltage category3
IP protection classIP20, with connected conductors
5SP9332-7KC47 — Electrical
ParameterValue
Rated current (AC)440 V
5SP9332-7KC47 — Mechanical
ParameterValue
Mounting positionany
Installation depth92 mm
SealableYes
5SP9332-7KC47 — Environmental
ParameterValue
Halogen-freeYes
Silicone-freeYes
Influence of surrounding temperaturePeriodically +55°C, max. 95% humidity

Product details

What this 50 kA SCCR means for your panel

The 5SP9332-7KC47 is a SENTRON miniature circuit breaker rated 32 A with a C tripping curve and a 50 kA breaking capacity at 400 V AC per IEC 60947-2. Three-pole construction (3P) with 4.5 width units on a standard mounting rail. The 92 mm installation depth and tunnel terminals top and bottom accept solid or stranded conductors from 0.75 to 50 mm² (AWG 14 to 2). Tightening torque spec is 2.5 to 3.5 N·m (22 to 31 lbf·in) — use a torque screwdriver; under-torqued terminals are the leading cause of thermal trips in the field. Overvoltage category 3 per IEC 60947-2, meaning it's rated for fixed-installation duty with transient overvoltages typical of distribution panels. Ambient temperature range -25 to +45 °C operating, -40 to +75 °C storage.

Halogen-free and silicon-free construction, which matters for installations with strict outgassing requirements (clean rooms, medical facilities, or sealed enclosures where corrosive byproducts from a fault event must be minimized). Touch protection integrated into the design.

Mechanical endurance and environmental tolerance

Rated for 20,000 mechanical switching cycles typical. Shock resistance tested to 150 m/s² at 11 ms half-sine (IEC 60068-2-27), vibration resistance to 50 m/s² at 25 to 150 Hz and 60 m/s² at 35 Hz for 4 seconds (IEC 60068-2-6). These ratings confirm the breaker holds calibration and doesn't nuisance-trip under the vibration levels common in industrial machinery or transport applications. Mounting position any, so it can be installed sideways or upside-down in a tight enclosure without derating. Periodic ambient tolerance to +55 °C and up to 95% humidity — covers most non-condensing indoor environments.

Frequently asked questions

What is the breaking capacity of 5SP9332-7KC47?

50 kA at 400 V AC per IEC 60947-2. That's the interrupting rating — it can clear a fault current up to 50,000 A without failing.

What conductor sizes does 5SP9332-7KC47 accept?

Solid or stranded conductors from 0.75 to 50 mm², which corresponds to AWG 14 to 2. Tunnel terminals top and bottom.

Where can I buy 5SP9332-7KC47?

Sourced and quoted to order against an RFQ through independent distribution. Availability and current pricing are confirmed at quote time.

Will 5SP9332-7KC47 drop into a panel specified around 5SJ6463-7?

Both are 3-pole C-curve MCBs on standard mounting rail, but the 5SP9332-7KC47 carries a 50 kA breaking capacity per IEC 60947-2 versus the 5SJ series' typical 10-15 kA per IEC 60898. The higher SCCR may require coordination review if the panel was designed around a lower interrupting rating.

MPN