Skip to main content
Siemens 5SP9416-7KC47 — 4-Pole MCB (DIN Rail)

Siemens 5SP9416-7KC47 SENTRON MCB, 4P C 16A 50kA 400V

MPN5SP9416-7KC47

Siemens SENTRON 5SP9 miniature circuit breaker, 4-pole, C-curve, 16 A, 50 kA breaking capacity at 400 V AC per IEC 60947-2, tunnel terminals, IP20.

Sourced new & surplus through independent channelsAuthenticity-screened · ESD-safe packingListing updated Jul 2026

Specifications

5SP9416-7KC47 — Identification
ParameterValue
Type / order code5SP9
Brand nameSENTRON
5SP9416-7KC47 — Ratings
ParameterValue
Number of poles4
Pole configuration4P
Rated current (In), AC440 V
Rated current (In), AC16 A
Voltage typeAC/DC
5SP9416-7KC47 — Protection
ParameterValue
Tripping characteristic (trip curve)C
Rated breaking capacity, per IEC 60947-250 kA
Overvoltage category3
Degree of protection (IP)IP20, with connected conductors
Touch protectionYes
5SP9416-7KC47 — Mechanical
ParameterValue
Width in modular units6
Installation depth92 mm
Mounting positionany
SealableYes
5SP9416-7KC47 — Environmental
ParameterValue
Halogen-freeYes
Silicone-freeYes
Influence of ambient temperature (derating)Periodically +55°C, max. 95% humidity
5SP9416-7KC47 — Performance
ParameterValue
Mechanical service life (switching cycles, typ.)20 000

Product details

The Siemens 5SP9416-7KC47 is a SENTRON 5SP9 miniature circuit breaker, 4-pole, C-curve, rated 16 A at 400 V AC, with a 50 kA breaking capacity per IEC 60947-2. That 50 kA at 400 V means it can safely interrupt a fault current up to 50 000 A without upstream fuses needing to clear first — critical for high-fault panels close to the transformer. The C-curve (5–10× In) handles motor inrush and lighting loads without nuisance trips, while the 4-pole design switches all three phases plus neutral. Mounts on standard DIN rail or screw fixing, any position, with tunnel terminals top and bottom accepting solid or stranded conductors from 0.75 to 50 mm².

The 5SP9416-7KC47 occupies 6 width units (roughly 108 mm) on a standard DIN rail. Tunnel terminals top and bottom accept solid or stranded copper from 0.75 mm² up to 50 mm² — that 50 mm² top end lets you feed a main bus through the breaker rather than adding a separate terminal block. Tightening torque is 2.5 to 3.5 N·m (22–31 lbf·in). Ambient temperature range –25 to +45 °C, storage down to –40 °C. Shock and vibration tested per IEC 60068-2-27 and -6, so it holds up in transport and industrial floor conditions.

Frequently asked questions

What is the breaking capacity of 5SP9416-7KC47?

50 kA at 400 V AC per IEC 60947-2. That is the rated short-circuit breaking capacity — the maximum fault current it can safely interrupt at that voltage.

What conductor sizes does the 5SP9416-7KC47 accept?

Solid and stranded conductors from 0.75 mm² up to 50 mm². AWG 14 to 2. The tunnel terminals top and bottom accept the full range.

Where can I buy 5SP9416-7KC47?

Sourced and quoted to order against an RFQ through independent distribution. Availability and current pricing are confirmed at quote time — submit an RFQ for a firm commitment.

What compliance documentation does Siemens provide for 5SP9416-7KC47?

The part carries IEC 60947-2 certification. The SENTRON series typically supports RoHS and REACH declarations; request specific documentation at quote time.

MPN
5SP9416-7KC47