Siemens 5SP9420-7KC47 — 4-Pole MCB (DIN Rail)

Siemens SENTRON 5SP9420-7KC47 MCB, 4P C 20A, 50kA IEC 60947-

MPN5SP9420-7KC47

Siemens SENTRON 5SP series, miniature circuit breaker, 4-pole, C-curve, 20 A, 50 kA breaking capacity per IEC 60947-2 at 400 V AC, 6 MW, IP20.

Sourced new & surplus through independent channelsAuthenticity-screened · ESD-safe packingListing updated Jul 2026

Specifications

5SP9420-7KC47 — Identification
ParameterValue
Brand nameSENTRON
5SP9420-7KC47 — Ratings
ParameterValue
Number of poles4
Pole configuration4P
Rated current (In), AC440 V
Voltage typeAC/DC
5SP9420-7KC47 — Protection
ParameterValue
Tripping characteristic (trip curve)C
Rated breaking capacity, per IEC 60947-250 kA
Overvoltage category3
Pollution degree3
Degree of protection (IP)IP20, with connected conductors
Touch protectionYes
5SP9420-7KC47 — Mechanical
ParameterValue
Width in modular units6
Installation depth92 mm
Fastening / mounting methodStandard mounting rail and screw fixing
Mounting positionany
Tightening torque, max.75 °C
Tightening torque, min.-40 °C
SealableYes
5SP9420-7KC47 — Environmental
ParameterValue
Halogen-freeYes
Silicone-freeYes
Influence of ambient temperature (derating)Periodically +55°C, max. 95% humidity
5SP9420-7KC47 — Performance
ParameterValue
Mechanical service life (switching cycles, typ.)20 000

Product details

What this 4-pole MCB delivers

Snaps onto standard DIN rail or accepts screw fixing, with any mounting position allowed — no derating needed for horizontal or inverted orientation. The 92 mm installation depth and 6 modular width units (roughly 108 mm) mean it occupies three times the space of a single-pole unit, so plan the DIN-rail layout accordingly.

Rated for 20 000 mechanical switching cycles, this breaker outlasts many residential-grade MCBs (typically 10 000 cycles) — a practical advantage in applications with frequent manual switching or automated load shedding. Survives shock to 150 m/s² at 11 ms half-sine and vibration to 50 m/s² at 25–150 Hz, per IEC 60068-2-27 and -6, so it holds up on vibrating machinery or near conveyor drives. The -40 °C to +75 °C operating range covers cold storage and hot panel interiors, though periodic ambient peaks to +55 °C with 95% humidity are the design reference. Halogen-free and silicon-free construction reduces toxic smoke in a fire and avoids silicone outgassing that can foul relay contacts or sensitive electronics in the same enclosure.

Frequently asked questions

Where can I buy 5SP9420-7KC47 and how do I get a price?

This part is sourced through independent distribution channels. Submit an RFQ through this listing; availability and current pricing are confirmed at quote time.

Will 5SP9420-7KC47 drop into a panel specified around 5SL4363-7 without rewiring?

No — the 5SL4363-7 is a 3-pole MCB with 10 kA breaking capacity per IEC 60947-2, while the 5SP9420-7KC47 is a 4-pole unit with 50 kA breaking capacity. The 5SP is 6 MW wide versus 3 MW for the 5SL, so it needs more DIN-rail space and a different wiring scheme for the fourth pole. They are not drop-in interchangeable.

What compliance documentation does this brand provide for 5SP9420-7KC47?

The SENTRON series carries IEC 60947-2 certification for breaking capacity and is designed for pollution degree 3 and overvoltage category III installations. The halogen-free and silicon-free construction supports environmental compliance requirements. Specific RoHS/REACH declarations are available from the manufacturer on request.

MPN
5SP9420-7KC47