Skip to main content
Siemens 5SP9425-7KC47 — 4-Pole MCB (DIN Rail)

Siemens 5SP9425-7KC47 SENTRON MCB, 4P C 25 A, 50 kA IEC 6094

MPN5SP9425-7KC47

Siemens SENTRON 5SP9 series, 5SP9425-7KC47 miniature circuit breaker, 4-pole, C-curve, 25 A rated, 50 kA breaking capacity per IEC 60947-2, 400 V AC, 50 Hz.

Sourced new & surplus through independent channelsAuthenticity-screened · ESD-safe packingListing updated Jul 2026

Specifications

5SP9425-7KC47 — Identification
ParameterValue
Type / order code5SP9
Brand nameSENTRON
5SP9425-7KC47 — Ratings
ParameterValue
Number of poles4
Pole configuration4P
Rated current (In), AC440 V
Rated current (In), AC25 A
Voltage typeAC/DC
5SP9425-7KC47 — Protection
ParameterValue
Tripping characteristic (trip curve)C
Rated breaking capacity, per IEC 60947-250 kA
Overvoltage category3
Degree of protection (IP)IP20, with connected conductors
Touch protectionYes
5SP9425-7KC47 — Mechanical
ParameterValue
Width in modular units6
Installation depth92 mm
Mounting positionany
SealableYes
5SP9425-7KC47 — Environmental
ParameterValue
Halogen-freeYes
Silicone-freeYes
Influence of ambient temperature (derating)Periodically +55°C, max. 95% humidity
5SP9425-7KC47 — Performance
ParameterValue
Mechanical service life (switching cycles, typ.)20 000

Product details

The Siemens SENTRON 5SP9425-7KC47 is a 4-pole miniature circuit breaker rated 25 A with a C tripping characteristic, designed for 400 V AC / 50 Hz systems. Its 50 kA breaking capacity per IEC 60947-2 means it can safely interrupt fault currents up to that level without upstream cascading — critical for high-fault-capacity industrial panels where selectivity with upstream devices is a design requirement.

Ratings and fit

The C-curve (5–10× In magnetic trip) suits moderate inrush loads like motor starters, small transformers, and lighting banks — common in mixed-load distribution panels. The 4-pole version (4P) switches all three phases plus neutral, required for TN-S or TT systems where neutral isolation is needed. Solid and stranded conductors from 0.75 to 50 mm² (AWG 14–2) are accepted at the tunnel terminals, top and bottom. Terminal torque spec is 2.5–3.5 N·m (22–31 lbf·in). The 6 width units (approx. 108 mm on a DIN rail) and 92 mm installation depth fit standard 18 mm modular enclosures.

Deployment context

Mounts on standard DIN rail or via screw fixing; any mounting position is allowed. Ambient temperature range is –25 to +45 °C, with periodic excursions to +55 °C at 95% humidity. IP20 with connected conductors — suitable for enclosed panel use, not for wet or outdoor locations without a secondary enclosure.

Frequently asked questions

What is the breaking capacity of 5SP9425-7KC47?

It is rated 50 kA at 400 V AC per IEC 60947-2. That rating governs its ability to clear high fault currents without rupturing — a key coordination figure for panel designers.

What conductor sizes does 5SP9425-7KC47 accept?

Solid and stranded conductors from 0.75 to 50 mm² (AWG 14–2). Both top and bottom tunnel terminals accept the full range.

Where can I buy 5SP9425-7KC47?

This part is sourced and quoted to order against an RFQ through independent distribution channels. Availability and current pricing are confirmed at quote time — no stock count or lead-time figure is published here.

MPN
5SP9425-7KC47