Skip to main content
Siemens 5SP9432-7KC47 — Miniature Circuit Breakers (MCB)

Siemens 5SP9432-7KC47 SENTRON MCB, 4P C 32A, 50kA IEC 60947-

MPN5SP9432-7KC47

Siemens SENTRON 5SP9 series, 5SP9432-7KC47 miniature circuit breaker, 4-pole, C tripping characteristic, 32 A rated current, 440 V AC, 50 kA breaking capacity per IEC 60947-2, IP20.

Source DocumentedChannel stated on listing & quote
Condition PhotosReal unit photos / video on request
WhatsApp AnswersFast human replies for machine-down parts
Worldwide DispatchDHL/FedEx — transit quoted per order
Independent China distributor & sourcing agent· Listing updated Sep 2026

Specifications

5SP9432-7KC47 — Ratings
ParameterValue
Overvoltage category3

Product details

The Siemens SENTRON 5SP9432-7KC47 is a 4-pole miniature circuit breaker (MCB) with a C tripping characteristic, rated 32 A at 440 V AC, and a 50 kA breaking capacity tested to IEC 60947-2. It belongs to the 5SP9 design family within the SENTRON brand. The 50 kA interrupting rating at 400/440 V gives it headroom for high-fault installations where standard 10 kA or 15 kA MCBs would need upstream fusing or a current-limiting breaker.

Conductor termination and panel integration

Terminals accept solid and stranded conductors from 0.75 mm² up to 50 mm² (14 AWG to 2 AWG), with tunnel terminals at both top and bottom. Tightening torque is 2.5 to 3.5 N·m (22 to 31 lbf·in). The breaker snaps onto standard mounting rail (DIN rail) and can also be screw-fixed. It occupies 6 width units (roughly 108 mm on a 18 mm/module rail). Mounting position is any, and installation depth is 92 mm.

It withstands shock at 150 m/s² (11 ms half-sine) per IEC 60068-2-27 and vibration at 50 m/s² from 25 to 150 Hz and 60 m/s² at 35 Hz (4 sec) per IEC 60068-2-6. Mechanical service life is 20,000 switching cycles typical.

Frequently asked questions

How do I get current pricing and availability for 5SP9432-7KC47?

Submit an RFQ through this listing. The part is sourced to order; pricing and stock levels are confirmed at quote time against current distributor inventory.

What is the breaking capacity of 5SP9432-7KC47?

50 kA at 400/440 V AC per IEC 60947-2, which qualifies it for high-fault-capacity panels where standard 10 kA or 15 kA MCBs would require upstream current limiting.

What conductor sizes does 5SP9432-7KC47 accept?

Solid and stranded conductors from 0.75 mm² to 50 mm² (14 AWG to 2 AWG), with tunnel terminals at both top and bottom.

Will 5SP9432-7KC47 drop into a panel specified around 5SL4363-7 without rewiring?

Both are 4-pole Siemens MCBs with similar ratings, but the 5SP9 series uses a different housing design and terminal layout than the 5SL series. Verify terminal spacing and DIN-rail footprint against the existing panel layout before substitution — the 5SP9432-7KC47 occupies 6 width units, which may differ from the 5SL equivalent.

What compliance documentation does Siemens provide for 5SP9432-7KC47?

The product carries IEC 60947-2 certification for breaking capacity. The housing is halogen-free and silicon-free. For RoHS, REACH, and UL documentation, request the manufacturer's declaration of conformity with your RFQ.

MPN
5SP9432-7KC47