Siemens 5SQ2170-0KA03 — 1-Pole MCB (DIN Rail)

Siemens 5SQ2170-0KA03 SENTRON MCB, 1P, C, 3 A, 3 kA

MPN5SQ2170-0KA03

Siemens SENTRON 5SQ2170-0KA03, miniature circuit breaker, 1-pole, C-tripping characteristic, rated current 3 A, breaking capacity 3 kA acc. to EN 60898, rated voltage 240 V AC, 50 Hz, IP20, installation depth 55 mm.

Source DocumentedChannel stated on listing & quote
Condition PhotosReal unit photos / video on request
WhatsApp AnswersFast human replies for machine-down parts
Worldwide DispatchDHL/FedEx — transit quoted per order
Independent China distributor & sourcing agent· Listing updated Sep 2026

Specifications

5SQ2170-0KA03 — Identification
ParameterValue
Brand nameSENTRON
Number of poles1
5SQ2170-0KA03 — Electrical & Protection
ParameterValue
Tripping characteristic classC
Rated value (EN 60898)3 kA
Overvoltage category3
5SQ2170-0KA03 — Mounting & Connection
ParameterValue
Installation depth55 mm
5SQ2170-0KA03 — Environmental
ParameterValue
IP protection classIP20
5SQ2170-0KA03 — Other specifications
ParameterValue
Type of voltageAC/DC
Energy limiting class3
Number of width units1
Number of poles (Note)1P
Circuit-breaker (Design)5SQ
Current (at AC)3 A
Supply voltage (at AC)240 V
Supply voltage frequency50 Hz
Product function (neutral conductor switching)No

Product details

SENTRON T55 1-pole MCB, C-curve, 3 A

The Siemens 5SQ2170-0KA03 is a single-pole miniature circuit breaker from the SENTRON T55 series, rated 3 A with a C tripping characteristic. It breaks fault currents up to 3 kA per EN 60898 at 240 V AC, 50 Hz — the standard for final-subcircuit protection in commercial and light-industrial panels where the supply transformer impedance keeps prospective fault current below that level. The C-curve means the magnetic trip fires at 5 to 10 times rated current (15–30 A), so it handles the inrush of motor starters, contactor coils, and small transformers without nuisance tripping while still clearing a hard short. For resistive loads or long cable runs where inrush is lower, a B-curve sibling would trip faster; for high-inrush loads like welders, a D-curve would be a better fit. This one splits the difference for general mixed loads.

Frequently asked questions

What is the breaking capacity of the 5SQ2170-0KA03?

3 kA rated short-circuit capacity per EN 60898 at 240 V AC, 50 Hz. That is the standard domestic/commercial fault level; for industrial panels with higher prospective fault current you would step up to a 10 kA or 15 kA rated MCB.

Where can I buy the 5SQ2170-0KA03 and get a price?

This part is sourced to order against an RFQ through independent distribution. Submit a request for current pricing and availability — confirmed at quote time, no stock count or price figure published here.

Will the 5SQ2170-0KA03 drop into a panel built for the 5SQ2170-2YA15?

Yes — same 1-pole footprint, same 55 mm depth, same C-curve, same 3 kA breaking capacity. The only difference is the 5SQ2170-2YA15 is rated 1.6 A while this one is 3 A. It physically fits the same DIN-rail slot without rewiring, but verify the load current matches the new 3 A rating before swapping.