Skip to main content
Siemens 5SQ2170-0KA10 — 1-Pole MCB (DIN Rail)

Siemens SENTRON 5SQ2170-0KA10 MCB, 1P C-curve 10A, 3kA

MPN5SQ2170-0KA10

Siemens SENTRON T55 series, miniature circuit breaker 5SQ2170-0KA10, 1-pole, C-curve, 10 A, 3 kA breaking capacity per EN 60898, 240 V AC/DC.

Source DocumentedChannel stated on listing & quote
Condition PhotosReal unit photos / video on request
WhatsApp AnswersFast human replies for machine-down parts
Worldwide DispatchDHL/FedEx — transit quoted per order
Independent China distributor & sourcing agent· Listing updated Sep 2026

Specifications

5SQ2170-0KA10 — Identification
ParameterValue
Brand nameSENTRON
Number of poles1
5SQ2170-0KA10 — Electrical & Protection
ParameterValue
Tripping characteristic classC
Rated value (EN 60898)3 kA
Overvoltage category3
5SQ2170-0KA10 — Mounting & Connection
ParameterValue
Installation depth55 mm
5SQ2170-0KA10 — Environmental
ParameterValue
IP protection classIP20
5SQ2170-0KA10 — Other specifications
ParameterValue
Type of voltageAC/DC
Energy limiting class3
Number of width units1
Number of poles (Note)1P
Circuit-breaker (Design)5SQ
Current (at AC)10 A
Supply voltage (at AC)240 V
Supply voltage frequency50 Hz
Product function (neutral conductor switching)No

Product details

What this 1-pole C-curve MCB does in the panel

The single-pole (1P) form factor occupies one width unit on the DIN rail; installation depth is 55 mm, so it sits flush in standard consumer units and sub-distribution panels.

Drop-in check vs the 1.6 A sibling 5SQ2170-2YA15

The closest functional peer is 5SQ2170-2YA15 — same SENTRON T55 family, same 1-pole C-curve, same 55 mm depth, same 3 kA breaking capacity. The only difference is the current rating: 10 A on this code versus 1.6 A on the sibling. Both share the identical mechanical footprint and DIN-rail clip, so a panel specified around the 1.6 A version accepts the 10 A unit without rewiring. The swap is valid only if the downstream load and cable sizing support the higher rating.

The MCB carries an IP20 protection class (finger-safe terminals, no washdown rating). Overvoltage category 3 and energy limiting class 3 are specified per IEC/EN 60664 and EN 60898 respectively. Neutral conductor switching is not built in — this is a live-pole-only device. For compliance documentation (CE marking, RoHS, REACH, UL listing), the manufacturer's declaration applies to the SENTRON T55 series; confirm the specific certificate for this order code at quote time.

Frequently asked questions

Will 5SQ2170-0KA10 drop into a panel specified around 5SQ2170-2YA15 without rewiring?

Yes — both share the same 1-pole C-curve form factor, 55 mm depth, and DIN-rail clip. The swap is mechanically identical; just verify the downstream load and cable sizing support the 10 A rating instead of 1.6 A.

Where can I buy 5SQ2170-0KA10?

This part is sourced and quoted to order against an RFQ through independent distribution. Availability and current pricing are confirmed at quote time — send the request for a firm position.

What is the breaking capacity of 5SQ2170-0KA10?

3 kA rated value per EN 60898, which certifies it for final-subcircuit fault clearing in residential and light commercial distribution boards.

MPN
5SQ2170-0KA10