Siemens 5SQ2170-0KA13 — 1-Pole MCB (DIN Rail)

SENTRON 5SQ2170-0KA13 MCB, 1-Pole C-Curve 13A, 3kA

MPN5SQ2170-0KA13

SENTRON 5SQ2170-0KA13, miniature circuit breaker, 1-pole, C-curve, 13 A rated current, 240 V AC, 3 kA breaking capacity, IP20, 55 mm depth.

Source DocumentedChannel stated on listing & quote
Condition PhotosReal unit photos / video on request
WhatsApp AnswersFast human replies for machine-down parts
Worldwide DispatchDHL/FedEx — transit quoted per order
Independent China distributor & sourcing agent· Listing updated Sep 2026

Specifications

5SQ2170-0KA13 — Identification
ParameterValue
Brand nameSENTRON
Number of poles1
5SQ2170-0KA13 — Electrical & Protection
ParameterValue
Tripping characteristic classC
Rated value (EN 60898)3 kA
Overvoltage category3
5SQ2170-0KA13 — Mounting & Connection
ParameterValue
Installation depth55 mm
5SQ2170-0KA13 — Environmental
ParameterValue
IP protection classIP20
5SQ2170-0KA13 — Other specifications
ParameterValue
Type of voltageAC/DC
Energy limiting class3
Number of width units1
Number of poles (Note)1P
Circuit-breaker (Design)5SQ
Current (at AC)13 A
Acc. to IEC 60947-2 / rated value3 kA
Supply voltage (at AC)240 V
Supply voltage frequency50 Hz
Product function (neutral conductor switching)No

Product details

In a 240 V single-phase panel with a typical service entrance rating of 10 kA or higher, this MCB must be backed by an upstream overcurrent device with a lower let-through — a coordination check any panel builder runs. Energy limiting class 3 means the breaker restricts the let-through energy (I²t) to a defined low level during a short circuit, which helps protect downstream components and reduces arc-flash hazard. The AC/DC voltage type means the same unit can be applied on a DC control circuit up to the rated voltage — though the 3 kA breaking capacity is only confirmed at AC; DC derating applies per the manufacturer's curves.

Integration note: panel fit and wiring

Snap-on DIN rail mounting, 1 width unit, 55 mm depth — fits any standard 35 mm rail enclosure. No neutral switching on this 1-pole version (the neutral bar passes through or lands on a separate terminal block). The C-curve at 13 A is a common choice for lighting circuits, small fan motors, or control transformer primaries in a conveyor zone panel. If your BOM calls for a higher breaking capacity — say 10 kA for a service-entrance position — the 5SY4140-7 sibling carries that rating but at a 70 mm depth, so it won't drop into the same DIN rail footprint without checking the enclosure depth.

Frequently asked questions

Where can I buy 5SQ2170-0KA13 and get a price?

We source this part to order against an RFQ through the standard Siemens SENTRON distribution channel. Availability and current pricing are confirmed at quote time — submit an RFQ for a firm price and lead time.

What is the closest functional second-source to 5SQ2170-0KA13?

The 5SY4140-7 is a 1-pole C-curve MCB from the same SENTRON family, but it carries a 10 kA breaking capacity (EN 60898) and a 70 mm installation depth versus the 55 mm depth of the 5SQ2170-0KA13. It will not drop into the same panel without checking enclosure clearance.

Will 5SQ2170-0KA13 drop into a panel specified around 5SY4140-7 without rewiring?

No — the 5SQ2170-0KA13 has a 55 mm installation depth, while the 5SY4140-7 requires 70 mm. The DIN rail width (1 unit) and pole count (1) are the same, but the shallower depth may leave a gap in the panel cutout or require a different enclosure.