Skip to main content
Siemens 5SQ2170-2YA02 — 1-Pole MCB (DIN Rail)

SENTRON 5SQ2170-2YA02 Miniature Circuit Breaker, 1-Pole C 2A

MPN5SQ2170-2YA02

Siemens SENTRON MCB, 1-pole, C-curve, 2 A, 240 V AC, 3 kA per EN 60898, IP20, 1 MW DIN unit, 55 mm depth.

Source DocumentedChannel stated on listing & quote
Condition PhotosReal unit photos / video on request
WhatsApp AnswersFast human replies for machine-down parts
Worldwide DispatchDHL/FedEx — transit quoted per order
Independent China distributor & sourcing agent· Listing updated Sep 2026

Specifications

5SQ2170-2YA02 — Identification
ParameterValue
Product designationMiniature circuit breaker
Brand nameSENTRON
Number of poles1
5SQ2170-2YA02 — Electrical & Protection
ParameterValue
Tripping characteristic classC
Rated value (EN 60898)3 kA
Energy limitation class3
Overvoltage category3
5SQ2170-2YA02 — Mounting & Connection
ParameterValue
Installation depth55 mm
Modular width units1
5SQ2170-2YA02 — Environmental
ParameterValue
IP protection classIP20
Pollution degree3

Product details

The Siemens SENTRON 5SQ2170-2YA02 is a 1-pole miniature circuit breaker rated 2 A with C-curve tripping characteristic, designed for 240 V AC systems and carrying a 3 kA breaking capacity per EN 60898. It occupies a single modular width (18 mm) on DIN rail and installs at 55 mm depth — shallower than the standard 70 mm SENTRON units, which matters when panel depth is tight.

Snap-on DIN rail mounting, 1 MW slot. IP20 finger-safe with conductors connected; no neutral switching on this pole.

C-curve means magnetic trip between 5× and 10× rated current (10–20 A for this 2 A unit), suited for moderate inrush loads like small contactors or control transformers. Derate at elevated panel temperatures: 1.85 A at 40 °C, 1.6 A at 60 °C.

Frequently asked questions

What is the breaking capacity of 5SQ2170-2YA02?

3 kA per EN 60898 at 240 V AC.

Will 5SQ2170-2YA02 drop into a panel specified around 5SY4140-7?

Both are 1-pole SENTRON MCBs with C-curve and 1 MW DIN footprint, but the 5SQ2170-2YA02 is shallower at 55 mm vs 70 mm, and its breaking capacity is 3 kA vs 10 kA per EN 60898. It fits the same DIN rail and busbar system but at a lower fault-current rating — verify the panel's prospective short-circuit current before substituting.

What is the tripping characteristic of 5SQ2170-2YA02?

C-curve — magnetic trip between 5× and 10× rated current, designed for moderate inrush loads.

Where can I buy 5SQ2170-2YA02?

Sourced and quoted to order against an RFQ through independent distribution channels. Availability and current pricing confirmed at quote time.

MPN