Siemens 5SQ2170-2YA04 — 1-Pole MCB (DIN Rail)

SENTRON 5SQ2170-2YA04 Miniature Circuit Breaker, 1P C 4A 3kA

MPN5SQ2170-2YA04

SENTRON 5SQ2170-2YA04 miniature circuit breaker, 1-pole, C-curve, 4 A rated current, 3 kA breaking capacity per EN 60898, AC/DC rated voltage, 55 mm depth, IP20 finger-safe terminals.

Source DocumentedChannel stated on listing & quote
Condition PhotosReal unit photos / video on request
WhatsApp AnswersFast human replies for machine-down parts
Worldwide DispatchDHL/FedEx — transit quoted per order
Independent China distributor & sourcing agent· Listing updated Sep 2026

Specifications

5SQ2170-2YA04 — Identification
ParameterValue
Product designationMiniature circuit breaker
Brand nameSENTRON
Number of poles1
5SQ2170-2YA04 — Electrical & Protection
ParameterValue
Tripping characteristic classC
Rated value (EN 60898)3 kA
Energy limitation class3
Overvoltage category3
5SQ2170-2YA04 — Mounting & Connection
ParameterValue
Installation depth55 mm
Modular width units1
5SQ2170-2YA04 — Environmental
ParameterValue
IP protection classIP20
Pollution degree3
5SQ2170-2YA04 — Other specifications
ParameterValue
Type of voltageAC/DC
Design of the productMiniature circuit breaker 5SQ
Number of poles (Note)1P
Supply voltage (at AC)240 V
Supply voltage frequency50 Hz
Operational current (at AC)4 A
Product function (Neutral conductor switching)No

Product details

The SENTRON 5SQ2170-2YA04 is a miniature circuit breaker (MCB) from the 5SQ series, designed for branch-circuit overcurrent protection in distribution boards and control panels. Single-pole (1P) construction with a C-curve trip characteristic — the standard choice for moderate inrush loads like small motors, transformers, and lighting banks where the start-up surge exceeds a B-curve's tolerance but doesn't need a D-curve's headroom. Rated 4 A at 240 V AC, 50 Hz, with a 3 kA breaking capacity certified to EN 60898. That 3 kA figure governs its fault-clearing ability at the panelboard's service entrance or subfeed — adequate for residential and light commercial final circuits where the prospective short-circuit current stays under that threshold. The AC/DC voltage rating means it can also switch DC loads up to the same voltage class, though the DC breaking capacity follows a different derating curve; confirm the DC application against the manufacturer's data. Snaps onto a standard DIN rail, occupying one modular width unit. Installation depth is 55 mm.

Panel Fit & Integration

Degree of pollution 3 and overvoltage category III suit it for fixed installations inside an enclosure where conductive contamination is controlled — typical for commercial distribution boards and industrial control panels. The energy limitation class 3 indicates the breaker limits let-through energy during a fault, aiding downstream coordination. No neutral-conductor switching — this is a straight single-pole line-side breaker. For applications requiring switched neutral, pair it with a separate switched-neutral terminal block.

Frequently asked questions

What is 5SQ2170-2YA04's number of poles?

Single-pole (1P) construction. It protects one phase conductor and does not switch the neutral.

What type of voltage does 5SQ2170-2YA04 accept?

Rated for both AC and DC operation. The AC rating is 240 V at 50 Hz; confirm DC voltage and breaking capacity against manufacturer data for DC applications.

How does 5SQ2170-2YA04 compare to the 5SY4140-7?

The 5SY4140-7 is a later-generation SENTRON MCB with a higher 10 kA breaking capacity (EN 60898), deeper 70 mm installation depth, and broader operating temperature range (-40 to +75 °C). The 5SQ2170-2YA04 has a shallower 55 mm depth and a 3 kA rating — it fits where panel space is tight and fault current is low, but the 5SY4140-7 offers more fault-clearing headroom and environmental tolerance.

Will 5SQ2170-2YA04 drop into a panel specified for 5SY4140-7?

Both share the same 1-module DIN-rail footprint and single-pole form factor, so mechanical fit is identical. However, the 5SQ2170-2YA04 is 55 mm deep versus 70 mm for the 5SY4140-7 — it will fit, but the shallower depth may leave a gap behind the DIN rail if the panel was designed for the deeper breaker. The electrical difference is the 3 kA vs 10 kA breaking capacity; verify the available fault current at the panel before substituting.

MPN
5SQ2170-2YA04